4
C CONTROLLER SETTING UTILITY
Module information
Event history
Item
Start monitoring
or
Stop monitoring
button
System info
button
*1
Input
*1
Output
Buffer memory,
CPU shared memory
Address format
Offset
Latest error
Numeric format
Display format
4
- 16
4.5 Module Monitoring Tab
Table 4.9 Description of the Module monitoring tab (continued)
Module monitoring
SRAM monitoring
Starts or stops monitoring the C Controller module.
"*" flashes in the upper right of the button during monitoring.
These buttons are disabled in the offline status.
Displays the System information screen.
This button is disabled during monitoring.
Monitors the input (X) of the module specified in "Slot No.".
0: OFF
1: ON
Monitors the output (Y) of the module specified in "Slot No.".
0: OFF
1: ON
Double-clicking this item enables forced output using the data setting screen.
(
Page 4-10, Section 4.4 (3))
Specifying an intelligent function module in "Slot No." enables monitoring of the
buffer memory.
Specifying a CPU module in "Slot No." enables monitoring of the CPU shared
memory.
Double-clicking this item enables forced output by using the data setting screen.
(
Page 4-10, Section 4.4 (3))
(Default: the value to be monitored, Setting range: see below)
•"Display format" is "16 bits": -32768 to 32767 (0
•"Display format" is "32 bits": -2147483648 to 2147483647 (0
Select the numeric format for "Address" (Default: "HEX.")
Select an address of the buffer memory or CPU shared memory to be monitored.
(Default: 0, Setting range: see below)
•Buffer memory: 0 or more (
•CPU shared memory: 0 to FFF
For the Q06CCPU-V(-B), the range from 2710
C Controller Module User's Manual (Hardware Design, Function
Explanation)
Displays an error code of the latest error occurred in an intelligent function module.
"No error" is displayed when the error code is "0".
"-" is displayed when monitoring other than an intelligent function module.
For error codes of the intelligent function module, refer to the manual for each
module.
Select a numeric format for the buffer memory or CPU shared memory.
(Default: "HEX.")
Select a display format for the buffer memory or CPU shared memory.
(Default: "16 bits")
* 1 The displayed input and output data covers the points assigned in Parameter settings (I/O
assignment settings) for the module mounted to the specified slot No.
Online operation
Description
to FFFF
)
H
H
Manual for the CPU used)
, 2710
to 5F0F
H
H
H
to 5F0F
are not available.
H
H
System settings
Reference
page
Page 4-17
to FFFFFFFF
)
H
H