CC IE CONTROL UTILITY
Module information
Online operation
Item
Link device refresh cycle
Routing parameter
button
Target module
Start I/O No.
Channel No.
Default
button
Check
button
Refresh parameters
button
Network range assignment
button
Operation settings
Network type
Mode
Network No.
Group No.
Station No.
Table 7.12 Description of Parameter settings tab (continued)
Parameter settings
Set a refresh cycle for link devices. (In increments of ms)
When using both the CC-Link IE Controller Network and MELSECNET/H network, set the same
value as the value set in MELSECNET/H utility.
To enable the "Block data assurance per station" setting (
10ms or more for "Link device refresh cycle", and set refresh parameters.
Setting 0 for "Link device refresh cycle" disables any refresh with all refresh parameter settings
Refresh parameters
deleted, and disables the
(Default: 100, Setting range: 0, 10 to 1000)
For further details, refer to the C Controller Module User's Manual (Hardware Design, Function
Explanation).
Displays the "Routing parameter settings" screen. (
Select a module to configure. (Default: 1)
The numbers for this item will be automatically rearranged in ascending order of start I/O numbers
when saving the parameter setting file or when switching the tab.
Set a start I/O No. of a CC-Link IE Controller Network module.
(Setting range: 0 to FE0
(The set value must be unique, and not duplicated with the one for
H
another CC-Link IE Controller Network module.))
Set a channel No. of a CC-Link IE Controller Network module.
The set value is used to open the channel from Device monitoring utility or a user program
(MELSEC data link functions).
Channel No. must be unique, and not duplicated with the one for another CC-Link IE Controller
Network module.
Sets the operation settings, network range assignments, and refresh parameters to default values.
Checks for any setting error.
Displays the "Refresh parameter settings" screen. (
To enable the Block data assurance per station" setting (
10ms or more for "Link device refresh cycle", and set refresh parameters.
Displays the "Network range assignment" screen. (
When "CC IE Control (Control station)" is selected for "Network type", this button is enabled.
Specify the CC-Link IE Controller Network module operation.
Set a type of the CC-Link IE Controller Network module.
(Default: "CC IE Control (Control station)")
Set a mode of the CC-Link IE Controller Network module.
"Line test" can be set when "CC IE Control (Control station)" is selected for "Network type".
(Default: "Online")
Set a network No. of the CC-Link IE Controller Network module.
(Default: 1, Setting range: 1 to 239)
Set a group No. of the CC-Link IE Controller Network module.
(Default: 0, Setting range: 0 to 32)
Set a station No. of the CC-Link IE Controller Network module.
(Default: 1, Setting range: 1 to 120)
Target settings
Description
Page 7-33, Section 7.5 (7)), enter
button.
Page 7-25, Section 7.5 (3))
Page 7-27, Section 7.5 (4))
Page 7-33, Section 7.5 (7)), enter
Page 7-29, Section 7.5 (5))
7.5 Parameter Settings Tab
1
2
3
4
5
6
7
8
7
- 24