Mitsubishi Electric Q12DCCPU-V User Manual page 167

Melsec-q series c controller module
Hide thumbs Also See for Q12DCCPU-V:
Table of Contents

Advertisement

6
MELSECNET/H UTILITY
Parameter settings
Online operation
Item
Link device refresh cycle
Routing parameter
button
Target module
Start I/O No.
Channel No.
Refresh parameters
button
Check
button
Default
button
Operation settings
Network No.
Group No.
Network type
Mode
Return
Table 6.22 Description of the Parameter setting tab (continued)
Target settings
Set the refresh cycle of the link device. (In increments of ms)
When using both the CC-Link IE Controller Network and MELSECNET/H, set the same value as
the value set in CC IE Control utility.
When enabling Block data assurance per station (
to the "Link device refresh cycle" and set "Refresh parameters".
If 0 is set, refresh is not performed, all the settings for the refresh are cleared, and the
Refresh parameters
button is disabled.
(Default: 100, Setting range: 0, 10 to 1000)
For details of the link device refresh cycle, refer to the C Controller Module User's (Hardware
Design, Function Explanation).
Displays the Routing parameter settings screen. (
Select a module to configure. (Default: 1)
The numbers for this item will be automatically rearranged in ascending order of start I/O numbers
when saving the parameter setting file or when switching the tab.
Set the start I/O No. of the MELSECNET/H module.
(Setting range: 0 to FE0
(Note that the number must be unique and cannot be duplicated with the
H
start I/O No. of other MELSECNET/H module.)
Set the channel No. of the MELSECNET/H module.
Use this value when opening the channel from Device monitoring utility or a user program
(MELSEC data link function).
For the Q06CCPU-V-B, this setting is not available.
The channel No. must be unique and cannot be duplicated with a channel No. of other
MELSECNET/H modules.
Displays the Refresh parameter setting screen. (
When enabling Block data assurance per station, (
more to the "Link device refresh cycle" and set "Refresh parameters".
Checks for any setting error.
Set the operation settings, network range assignments, and refresh parameters back to default.
Operation settings for the MELSECNET/H module.
Set the network No. of the MELSECNET/H module.
(Default: 1, Setting range: 1 to 239)
Set the group No. of the MELSECNET/H module.
(Default: 0, Setting range: 0 to 32)
Set the type of the MELSECNET/H module.
(Default: "MNET/H mode (Control station)")
Set the mode of the MELSECNET/H module. (Default: "Online")
Return setting of the control station.
This setting is available when any of the following is selected for "Network type".
•MNET/H mode (Control station)
•MNET/10 mode (Control station)
•MNET/H Ext. mode (Control station)
(Default: "Return as control station")
Description
Page 6-37, Section 6.6 (6)), set 10 or more
Page 6-31, Section 6.6 (3))
Page 6-33, Section 6.6 (4))
Page 6-37, Section 6.6 (6)), set 10 or
6.6 Parameter Settings Tab
1
2
3
4
5
6
7
(To the next page)
8
6
- 28