7
CC IE CONTROL UTILITY
(4) Refresh parameter settings screen
Item
Assignment method
Link side
Device name
Points
Start
End
CPU side
Device name
Points
Start
End
Default
button
Check
button
End
button
Cancel
button
7
- 27
7.5 Parameter Settings Tab
Refresh parameters are set on this screen.
Figure 7.25 Refresh parameter settings screen
Table 7.14 Description of Refresh parameter settings screen
How to enter the device range data can be switched between Points/Start and Start/End styles.
(Default: "Start/End")
Set refresh parameters of the module selected on the "Parameter settings" tab.
Up to 64 refresh parameters can be set.
Since duplicated device setting is not allowed, prevent any overlapped settings.
Set a link device name to be refreshed.
(Default:
Page 7-28, Section 7.5 (4) (a), Setting range:
Set points of the link device to be refreshed.
(Default:
Page 7-28, Section 7.5 (4) (a), Setting range:
Set the start No. of the link device to be refreshed.
(Default:
Page 7-28, Section 7.5 (4) (a), Setting range:
Set the end No. of the link device to be refreshed.
(Default:
Page 7-28, Section 7.5 (4) (a), Setting range:
Displays refresh parameters of the CPU module.
Data corresponding to respective "Link side" settings are shown.
Displays the name of the device whose data are refreshed onto the CPU module.
(Range:
Page 7-28, Section 7.5 (4) (b))
Displays the points of the device whose data are refreshed onto the CPU module.
The points is the same as those shown in "Points" of "Link side".
Displays the start No. of the device whose data are refreshed onto the CPU module.
The start No. is the same as that shown in "Start" of "Link side".
Displays the end No. of the device whose data are refreshed onto the CPU module.
The end No. is the same as that shown in "END" of "Link side".
Resets the "Link side" and "CPU side" settings back to defaults.
Checks the "Link side" and "CPU side" settings for errors.
Saves the settings and closes the "Refresh parameter settings" screen.
Closes the "Refresh parameter settings" screen without saving the settings.
Description
Page 7-28, Section 7.5 (4) (b))
Page 7-28, Section 7.5 (4) (c))
Page 7-28, Section 7.5 (4) (c))
Page 7-28, Section 7.5 (4) (c))