Mitsubishi Electric Q12DCCPU-V User Manual page 168

Melsec-q series c controller module
Hide thumbs Also See for Q12DCCPU-V:
Table of Contents

Advertisement

6
MELSECNET/H UTILITY
Parameter settings
Online operation
Item
Network range assignment
Total stations
Assignment method
Monitoring time
Switch screens
Points
Start
End
Specify I/O master Sta.
Specify reserved Sta.
button
Equal assignment
button
Supplementary settings
Clear
button
6
- 29
6.6 Parameter Settings Tab
Table 6.22 Description of the Parameter setting tab (continued)
Target settings
Assign network ranges.
•MNET/H mode (Control station)
•MNET/10 mode (Control station)
•MNET/H Ext. mode (Control station)
Set a total number of stations (including the control station) to the target network.
(Default: 2)
Switches the device range input method between Points/Start and Start/End.
(Default: "Start/End")
Set the monitoring time for the link scan time. (In increments of 10ms)
(Default: 200, Setting range: 1 to 200)
Select the link device to which network range is to be assigned.
"Low speed LB" and "Low speed LW" can be set when MNET/H mode (Control station) or MNET/H
Ext. mode (Control station) is selected for "Network type".
(Default: "LB/LW settings")
Set the No. of the link device points assigned to the target station.
This setting is available when "Point/Start" is selected for "Assignment method".
(Default: "(blank)", Setting range:
Set the start No. of the link device assigned to the target station.
(Default: "(blank)", Setting range:
Set the end No. of the link device assigned to the target station.
This setting is available when "Start/End" is selected for "Assignment method".
(Default: "(blank)", Setting range:
Sets the selected station as an I/O master station of the link device (LX/LY), or cancels the setting.
This button is enabled when "(LX/LY) settings (1)" or "(LX/LY) settings (2)" is selected for "Switch
button
screens".
Sets the selected station as a reserved station, or cancels the setting.
Displays the Equal assignment screen. (
button
Displays the Supplementary settings screen. (
Clears the "Points", "Start", and "End" settings and then sets the "Total stations" and "Monitoring
time" settings back to default.
Description
Page 6-30, Section 6.6 (2) (a))
Page 6-30, Section 6.6 (2) (a))
Page 6-30, Section 6.6 (2) (a))
Page 6-35, Section 6.6 (5))
Page 6-37, Section 6.6 (6))