6
MELSECNET/H UTILITY
Module information
Item
Link device refresh time
Current
Start monitoring
or
Stop monitoring
button
1 Slot to 4 Slot
Start I/O No.
Channel No.
Network No.
Group No.
Sta. No.
Type
Status
Link scan time
Details
button
6
- 3
6.2 Module Information Tab
Table 6.2 Description of the Module information tab (continued)
Error history monitoring
Other station monitoring
Displays current total link device refresh time.
"-" appears when Link device refresh cycle (
6.6) is 0ms.
Starts or stops monitoring of the MELSECNET/H module.
"*" flashes in the upper right of the button during monitoring.
These buttons are disabled in the offline status.
Displays information of the CC-Link module.
The information is displayed in ascending order of start I/O No.
Displays the start I/O No. of the MELSECNET/H module.
Displays the channel No. of the MELSECNET/H module.
"-" appears when "Channel No." has not been set. (
Section 6.6)
Displays the network No. of the MELSECNET/H module.
"-" appears when "Network No." has not been set. (
Section 6.6)
Displays the group No. of the MELSECNET/H module.
"-" appears when "Group No." has not been set. (
Section 6.6)
Displays the station No. of the MELSECNET/H module.
Displays the type of the MELSECNET/H module.
Displays the communication status of the MELSECNET/H module.
(
Page 6-3, Section 6.2 (2) (a))
Displays the scan time of the MELSECNET/H module.
(In increments of ms)
Opens the Module information tab. (
This button is disabled during monitoring.
(a) Communication status
Details of communication states are given below.
Display
In data link
Suspend data link (Other)
Suspend data link (Hostself)
Baton pass (No area)
Baton pass (Parameter Halt)
Baton pass (No Receive)
Disconnecting (no baton)
Disconnecting (Link error)
Testing
Resetting
Description
Page 6-27, Section
Page 6-27,
Page 6-4, Section 6.2 (3))
Table 6.3 Details of communication states
Data link is being performed.
Cyclic transmission was stopped from the other
station.
Cyclic transmission was stopped by the host station.
No B/W transmission assignment to the host station.
An error has detected in any of the host station
parameter.
Common parameters have not been received.
Station No. duplication, or cable not connected.
Cable not connected.
Online or offline test is being conducted.
Hardware error.
Corresponding
SB
Page 6-27,
Page 6-27,
SB0044
Description
Corresponding
SW
SW0040
SW0041
SW0042
SW0047