Mitsubishi Electric Q12DCCPU-V User Manual page 314

Melsec-q series c controller module
Hide thumbs Also See for Q12DCCPU-V:
Table of Contents

Advertisement

10
PROGRAMMING USING MELSEC DATA LINK
FUNCTIONS
(2) Dedicated device types for Q series bus interface
Device types
Code
DEC.
HEX.
501
1F5
H
502
1F6
H
503
1F7
H
504
1F8
H
(3) Device types for accessing the CC-Link modules
Device type
Code
DEC.
HEX.
1
1
H
2
2
H
5
5
H
14
E
H
25
19
H
28
1C
H
33
21
H
36
24
H
37
25
H
50
32
H
-32768
8000
H
-32736
8020
H
10
- 14
10.12 Device Types for the MELSEC Data Link Function
Table 10.7 Q series bus interface dedicated device types
*1
Device name
DevSPB1
CPU shared memory (area for CPU No.1)
DevSPB2
CPU shared memory (area for CPU No.2)
DevSPB3
CPU shared memory (area for CPU No.3)
DevSPB4
CPU shared memory (area for CPU No.4)
* 1 The device name specification (macro) is defined in this function's include file "MdFunc.h".
Page 9-9, Section 9.4)
* 2 The device cannot be used in the mdRandR, mdRandREx, mdRandW, mdRandWEx, mdDevSet,
mdDevSetEx, mdDevRst, or mdDevRstEx function.
Table 10.8 Device types for accessing CC-Link module
*1
Device name
DevX
Own station RX
DevY
Own station RY
DevSM
Own station SB (link special relay for CC-Link)
DevSD
Own station SW (link special register for CC-Link)
DevQSB
Own station SB (link special relay for CC-Link)
DevQSW
Own station SW (link special register for CC-Link)
DevMRB
Own station random access buffer
DevWw
Own station link register (for sending)
DevWr
Own station link register (for receiving)
DevSPB
Own station buffer memory
DevRBM
Other station buffer memory
DevRAB
Other station random access buffer
* 1 The device name specification (macro) is defined in this function's include file "MdFunc.h".
Page 9-9, Section 9.4)
* 2 The device cannot be used in the mdRandR, mdRandREx, mdRandW, mdRandWEx, mdDevSet,
mdDevSetEx, mdDevRst, or mdDevRstEx functions.
* 3 These (DevSM, DevQSB) are the same device.
* 4 These (DevSD, DevQSW) are the same device.
* 5 Note that maximum of one scan time may delay when the block data assurance per station
function is enabled and the link device is continuously accessed (mdSend, mdSendEx(1),
mdReceive(1), mdReceiveEx, mdDevSet, mdDevSetEx, mdDevRst, mdDevRstEx). (This is the
same behavior when the auto refresh method is selected as CC-Link refreshing method in the
QBF_ToBuf and QBF_FromBuf functions.)
Moreover, block data assurance per station cannot be used in dReadR, mdRandREx, mdReadW,
and mdRandWEx functions.
For details, refer to the following.
For block data assurance per station, refer to the C Controller Module User's Manual (Hardware
Design, Function Explanation).
For the MELSEC data link functions, refer to the HELP of the MELSEC data link function.
Device
*2
*2
*2
*2
Device
*5
*5
*5
*5
*5
*2
*2
(
*3
*4
*3
*4
(
(To the next page)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q06ccpu-vQ06ccpu-v-bSw3pvc-ccpu-e

Table of Contents