Mitsubishi Electric Q12DCCPU-V User Manual page 303

Melsec-q series c controller module
Hide thumbs Also See for Q12DCCPU-V:
Table of Contents

Advertisement

10
PROGRAMMING USING MELSEC DATA LINK
FUNCTIONS
Arrow
Access target
Programmable controller
CPU
C Controller module
CC-Link module (own
station)
Programmable controller
CPU
(other station)
Programmable controller
CPU
(other station in multiple
CPU system)
MELSECNET/H
module (host station)
CC-Link IE Controller
Network module (own
station)
Programmable controller
(other station)
Programmable controller
CPU (other station in
multiple CPU system)
Table 10.1 Access targets of MELSEC data link functions
No.
Setting of Device monitoring
Communication
given
path
above
Q series
1)
12: Q series bus interface
bus
Q series
12: Q series bus interface
bus
8n: CC-Link
CC-Link
(Channel No.8n)
8n: CC-Link
2)
CC-Link
(Channel No.8n)
8n: CC-Link
2)
CC-Link
(Channel No.8n)
5n: MELSECNET/H
MELSECNET/H
(Channel No.5n)
15n: CC-Link IE Controller
CC-Link IE
Network
Controller
Network
(Channel No.15n)
5n: MELSECNET/
MELSECNET/H
H(Channel No.5n)
3), 4)
15n: CC-Link IE Controller
CC-Link IE
Network
Controller
Network
(Channel No.15n)
5n: MELSECNET/H
MELSECNET/H
(Channel No.5n)
3), 4)
15n: CC-Link IE Controller
CC-Link IE
Network
Controller
Network
(Channel No.15n)
* 1 "n" indicates the last digit of the channel No. set in the CC-Link utility.
* 2 The logical station No. must be set in the <<Target settings>> tab of the CC-Link utility to access
the CPU that does not control other station CC-Link module.
* 3 "n" indicates the last digit of the channel No. set in the MELSECNET/H utility.
* 4 "n" indicates the last digit of the channel No. set in the CC IE Control utility.
* 5 The logical station No. must be set in the <<Target settings>> tab of the MELSECNET/H utility to
access the CPU that does not control the other station MELSECNET/H module.
* 6 The logical station No. must be set in the <<Target settings>> tab of the CC IE Control utility to
access the CPU that does not control the other station CC-Link IE Controller Network module.
10.1 Outline of MELSEC Data Link Functions
utility
Channel name
Station
Other
sta.
Own
sta.
Own
*1
sta.
Other
*1
sta.
Other
*1
sta.
*3
Own
sta.
*4
*3
Other
sta.
*4
*3
Other
sta.
*4
Remarks
Only CPU shared memory
accessible
Station No.: 0 to 63 (access to
control CPU of other station CC-Link
module)
*2
Station No.: 65 to 239
(access to CPU that does not control
other station CC-Link module)
Station No.: 1 to 64
(access to control CPU of other
station MELSECNET/H module)
Station No.: 1 to 120
(access to control CPU of other
station CC-Link IE Controller
Network module)
*5
Station No.: 65 to 239
(access to
CPU that does not control other
station MELSECNET/H module)
*6
Station No.: 65 to 239
(access to
CPU that does not control other
station CC-Link IE Controller
Network)
10
9
10
11
12
13
A
I
- 3