Mitsubishi Electric Q12DCCPU-V User Manual page 24

Melsec-q series c controller module
Hide thumbs Also See for Q12DCCPU-V:
Table of Contents

Advertisement

MANUAL PAGE ORGANIZATION
Relevant models
Whether the description of the section
applies to each model or not is shown
in the table.
Reference
The section in this manual or another
relevant manual that can be referred
to is shown after
Icon
Q12DCCPU-V
Q06CCPU-V
Q12DCCPU-V
Q06CCPU-V
Q12DCCPU-V
Q06CCPU-V
Q12DCCPU-V
Q06CCPU-V
A
- 22
5
CC-LINK UTILITY
5.6
Target Settings Tab
A logical station No. is set from the Target settings tab.
The logical station No. is used, when a target station is a multiple CPU system, to access
a programmable controller CPU other than the control CPU of the target station.
Note that the accesses indicated below does not require the logical station No. settings.
Page 5-17, "5.6 (4) Access that does not require a logical station No. setting"
(1) Precaution for the Target settings tab
Set a programmable controller CPU in "Target CPU"
(2) Target settings tab
Table 5.14 Description of Target settings tab
Module information
Other station monitoring
Online operation
Item
Select a module to configure.
Target module
(Default: "Slot 1")
Specify a logical station No. for the module selected in "Target module".
(Default: 65, Setting range: 65 to 239)
Logical sta. No.
The logical sta. No. is a logical number to be specified as "Sta. No." in Device monitoring utility and
an user program (MELSEC data link function).
Select a station No. of the CC-Link module controlled by a multiple CPU system.
Sta. No.
(Default: 0, Setting range: 0 to 63)
Select a CPU of the access target (CPU No. in a multiple CPU system).
Target CPU
(Default: 1, Setting range: 1 to 4)
Enters the added and changed data (Logical sta. No., Sta. No., and Target CPU) to the Target list.
Set
button
.
*
The above page illustration is for explanation purpose only, and is different from the actual page.
Q06CCPU-V-B
Q06CCPU-V-B
Q06CCPU-V-B
Q06CCPU-V-B
Q12DCCPU-V
Q06CCPU-V
Q06CCPU-V-B
Figure 5.10 Target settings tab
Target settings
Parameter settings
Test
Descriptio n
(To the next page)
5.6 Target Settings Tab
Section and title
The section number and title of the current
page can be easily identified.
All or part of the description applies each model.
The description applies to each model with some restrictions.
The description does not apply to each model.
Chapter
The chapter of the current page can be
easily identified by this indication on the
right side.
1
2
3
4
5
6
7
8
5
- 15
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q06ccpu-vQ06ccpu-v-bSw3pvc-ccpu-e

Table of Contents