Utype_Switch - Trango Systems TrangoLINK GigaPlus User Manual

6-40 ghz split architecture high capacity point-to-point microwave backhaul system
Table of Contents

Advertisement

EXAMPLE

utype_switch

SYNTAX
DESCRIPTION
Trango Systems, Inc.
Failover Counter: # of times the units have switched roles from active
to standby and vice-a-versa
Election Period: yes (during election period), no (not in election
period)
Debug Reg: For debugging
(CLI-config)# utype
Current utype:
Protection:
Redundancy Cable:
Remote Unit Status: standby detected
Sync Status:
Guard Time:
Failover Counter:
Election Period:
Debug Reg:
utype_switch
Default: N/A
Configuration Storage: N/A
utype_switch does not take any input parameter. Will perform utype
switch from Active to Standby.
This command only allowed on the Active unit. Can NOT be initiated
on Standby unit
utype_switch manually switch the Active to the Standby unit by
sending Switchover REQ to the standby unit.
This command is mainly used for image upgrades. During the image
upgrades, the standby unit can upgrade first and when done, perform
GigaPlus User Manual Rev 3.1
active
off
connected
Synchronized
15 seconds
0
no
(D6)0x00, (D5)0x00, (24)0x1F