Model; Mse - Trango Systems TrangoLINK GigaPlus User Manual

6-40 ghz split architecture high capacity point-to-point microwave backhaul system
Table of Contents

Advertisement

model

SYNTAX
DESCRIPTION

mse

SYNTAX
Trango Systems, Inc.
During IF and digital loopback, the transmitter signal from the far end will
still be present at the input to the IDU and may cause a poor result.
Therefore, the odupower OFF on the remote end of may be required to
eliminate any signal from the far end which may corrupt the result.
IMPORTANT: Make sure that the data ports are disabled before
executing the loopback if | dig comands or a loop may be formed on the
network.
All loopback modes will stop live traffic from passing across the link
model
Default: N/A
Configuration Storage: No
Display current ODU/IDU model and serial ID.
The following information are been displayed: ODU model, IDU model,
ODU Serial ID, IF Rev, IF Serial, IDU Model, IDU Serial ID for each radio
Mse
GigaPlus User Manual Rev 3.1
171