Before deployment it is a good idea to clear the syslog so that only events after the link
was commissioned are recorded. Run the syslog clear command.
(CLI-config)# syslog clear
(CLI-config)# syslog
Current 0:19:24:25.990
View the model information using the model command
(CLI-view)# model
IDU Model:
IDU Serial ID:
ODU Model:
ODU Serial ID:
Tx Freq Min:
Tx Freq Max:
Freq Duplex:
Enable Traps (Optional)
Traps can be used to notify external network monitoring devices that a threshold
parameter has been crossed. Thresholds re available for the following:
RSSI
MSE
BER
FER
OMU_TEMP
ODU_TEMP
OUT PORT UTILIZATION (percentage of max available)
IN PORT UTILIZATION (percentage of max available)
Link Down
If thresholds have been set and SNMP Trap assigned as an action, the crossing of the
threshold will generate a trap.
The current trap information using the trap command. The current trap manager IP
addresses are shown along with their individual status:
(CLI-config)# trap
Trango Systems, Inc.
IDU-GigaPlus-1
8480068
HP2-23-1200-3A
C110301327
22000.00
22400.00
1200.00 (MHz)