Trango Systems TrangoLINK GigaPlus User Manual page 117

6-40 ghz split architecture high capacity point-to-point microwave backhaul system
Table of Contents

Advertisement

Step 2: Change the Out of Band (OBM) Management IP Address
It is recommended to change the IP address on both ends of the radio first, before
installing the link to ensure that no problems will be encountered accessing the units in
the field from the destination network subnet
To change the IP address of the system, first check the ip settings using the ip command.
(CLI-config)# ipconfig
IP Address:
Subnet Mask:
Gateway IP:
ETH1 MAC:
ETH2 MAC:
Next, change the IP address and subnet mask. The system will not be responsive after
the change. Reconnect to the GigaPlus using the new IP address.
CLI-config)# ipconfig ip 10.14.1.41 255.255.254.0
IP Address:
Netmask:
SUCCESS
After re-connecting, change the gateway address as necessary.
(CLI-config)# ipconfig gateway 10.14.0.1
Gateway IP:
SUCCESS
Confirm that the changes are made:
(CLI-config)# ip
(CLI-config)# ipconfig
IP Address:
Trango Systems, Inc.
192.168.100.100
255.255.255.0
192.168.100.1
00:01:de:81:65:44
00:01:de:81:65:45
10.14.1.41
255.255.254.0
10.14.0.1
10.14.1.41
GigaPlus User Manual Rev 3.1