Command Line Interface (CLI) Based Configuration
CLI Based 1+0 Configuration
This section covers all the basics that are normally required for setting up the link using
either the telnet, SSH, or serial COM port to access the units. Step by step instructions
with session examples are given. The CLI interface has more functions available than the
Web Interface. Simply type the "?" to see a list of available commands.
Step 1: Connect to Each Unit via one of the CLI interfaces
In all the examples given, telnet was used, but the login procedure is similar for each. To
log into each units using the default IP address of 192.168.100.100.
Use the windows telnet program or any other telnet client program. When prompted
for the Login enter admin and for password, enter trango. The Trango Systems
command line interface application should respond as follows:
Microsoft Windows XP [Version 5.1.2600]
(C) Copyright 1985-2001 Microsoft Corp.
C:\Documents and Settings\user>telnet 192.168.100.100
CLI login: admin
Password:
Trango System:
When logging into the radio unit, the operator always enters the (CLI-view)# node, from
which only status of the system can be seen. To make changes to system settings, the
operator must enter the (CLI-config)# node of to allow changes to the system to be
made. Type the command config and the password trango. The password can be
changed later.
(CLI-view)# config
Password:
Trango Systems, Inc.
TrangoLINK GigaPlus Command Line Interface v1.3.0
GigaPlus User Manual Rev 3.1