Odurxagc - Trango Systems TrangoLINK GigaPlus User Manual

6-40 ghz split architecture high capacity point-to-point microwave backhaul system
Table of Contents

Advertisement

SYNTAX
DESCRIPTION

odurxagc

SYNTAX
DEFAULT VALUE
DESCRIPTION
Trango Systems, Inc.
odupower
odupower < on| off >
Default: OFF
Configuration Storage: Yes
odupower without any parameter will display the current status of ODU
power .
The command is used to Turn ON/OFF odupower.
The ODU is powered from the IDU over the IF cable with -48VDC
It is recommended to turn off the ODU power during initial installing of the
ODU on the tower and other maintenance
The response time for ODU power ON will vary depending upon the ODU
model. It is longer for HP ODUs
odurxagc <on | off>
Off
The command is used to set the odurx gain control loop in the system. This
controls the receive level into the IDU from the ODU and keeps the
received level within a predefined range. This helps to improve MSE and
maintain better system performance in fading conditions.
GigaPlus User Manual Rev 3.1
173

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TrangoLINK GigaPlus and is the answer not in the manual?

Table of Contents