2. On the joint bracket attached to the upstream unit, loosen screws (1), (2), (3), and (4).
3. Remove bracket [A] ( x1), rotate it 90 degrees, and re-fasten the screw. Changing the position of
this bracket aligns the oval cut-out horizontally and frees the joint bracket so it can slide from side to
side.
4. Look at the scale [B].
5. Slide the bracket to the left or right and tighten the screw.
6. If the deviation from center was toward the front, slide the bracket to the rear and tighten the screw
(1).
-or-
If the deviation from center was toward the rear, side the bracket to the front and tighten the screw
(1).
7. Tighten screws (2), (3), (4).
8. Do another test run, so that you can check the results of the adjustment.
Detecting Paper Skew
Do this check to detect the presence of skew in the paper path.
1. Make sure that the I/F cable of the unit is connected to the upstream unit.
2. If a peripheral unit is connected on the left side, disconnect it and pull it away.