Ricoh V-C3 D081 Field Service Manual page 651

Table of Contents

Advertisement

SC161-1
D
SC161-2
D
SC161-3
D
Illegal Copy Prevention Error
SC165
D
An abnormality was detected with the ICIB board at power on.
• ICIB connected incorrectly
• ICIB defective
Scanner fan lock (left fan)
SC180
D
The fan motor next to the SIOB did not switch on within 10 sec. after the CPU issued
the ON signal.
• Fan defective
• Foreign object interfering with operation of fan
• Motor harness loose, disconnected, or broken
• SIOB defective
Scanner fan lock: lamp stabilizer
SC181
D
The exposure lamp regulator fan is not rotating.
• Check the fan connections
• Fan defective
• Check SBU connection
• Check SIOB connection
• SBU defective
• SIOB defective
An error occurred when the ASIC executed a self-diagnostic report on the
BICU.
• Defective BICU
• Defective connection between BICU and SBU
The machine detects an error during an access to the Ri.
• Defective BICU board
The IPU fails to configure or initialize the DRAM.
• Defective BICU board