Sc Codes Group 3: Image Development - 1 - Ricoh V-C3 D081 Field Service Manual

Table of Contents

Advertisement

Skew control upper lower limit: C
SC272
C
The pulse total for Cyan skew control is not within the prescribed range.
• ITB not installed correctly.
• ITB defective
• Optical unit installed incorrectly
• Optical unit defective
MUSIC Continuous Failure
SC285
D
The MUSIC adjustment failed after four attempts.
• Fusing belt installed incorrectly
• Fusing belt surface scoured, scratched
• MUSIC sensors dirty, defective
SC Codes Group 3: Image Development – 1
SC300
D
Drum charge corona wire error: K
The output of the charge corona wire of the black PCU is abnormal.
• CGB power pack connection loose, broken defective
• Check CGB power pack connection to BCU
• CGB power pack defective
• BCU defective
• Replace OPC drum
SC301
D
AC charge output error: M
SC302
D
AC charge output error: C
SC303
D
AC charge output error: Y
An interrupt checks the status of the power pack every 10 ms. This SC is issued if the
VBCU detects a short in the AC charge for M, C, Y.