6. Troubleshooting
Code
Problem
• Vsg_reg (SP3121) is out of range (not within 4.0±0.2V).
• ID sensor fouled with dust, toner
• ITB undulating or out of position
Solution
• Remove the ITB unit.
• Make sure the belt is mounted correctly.
• Clean the windows of the ID sensors with alcohol and a clean cloth.
• Be sure to wipe the sensor apertures with a wet cloth. A dry cloth may generate static
22
ID Sensor LED Current Error
Problem
6
• LED PWM (SP3131) greater than 3000.
• ID sensor fouled with dust, toner
• ID sensor deteriorated
Solution
• Remove the ITB unit and check the ID sensors.
• Clean the windows of the ID sensors with alcohol and a clean cloth.
• Be sure to wipe the sensor apertures with a wet cloth. A dry cloth may generate static
• If the apertures are clean, then the LED of an ID sensor may have deteriorated. Replace
23
ID Sensor Output Error
554
which can attract dust.
which can attract dust.
the ID sensor plate.
Error, Problem, Solution