FGATE error: Feedback remains LOW for M write
SC235
D
After the start of timing to create the magenta image, the PFGATE register of the GAVD
does not assert.
• Harness between the VBCU and LDB unit disconnected, loose, or defective.
• LD unit defective
• IPU defective
• Controller board disconnected, defective
• HDD defective
FGATE error 1: Feedback remains HIGH for C write
SC236
D
After the start of timing to create the cyan image, the PFGATE register of the GAVD
did not assert.
• Harness between the VBCU and LDB unit disconnected, loose, or defective.
• LD unit defective
• IPU defective
• Controller board disconnected, defective
• HDD defective
FGATE error: Feedback remains LOW for C write
SC237
D
After the start of timing to create the cyan image, the PFGATE register of the GAVD
does not assert.
• Harness between the VBCU and LDB unit disconnected, loose, or defective.
• LD unit defective
• IPU defective
• Controller board disconnected, defective
• HDD defective
SC240
C
LD error: K
SC241
C
LD error: Y
SC242
C
LD error: M
SC243
C
LD error: C