Sc Codes Group 2: Exposure - Ricoh V-C3 D081 Field Service Manual

Table of Contents

Advertisement

CIS white level error
The shading data peak detected from the CIS is abnormal.
SC188
D
CIS gray balance adjustment error
The adjustment error occurs during the test after adjusting the gray balance.
SC189
D
Machine serial number error
SC195
D
The number registered for the machine serial number does not match.
• Confirm the correct serial number of the machine in the specifications
• Re-input the serial number.
Important: When SC195 occurs, the serial number must be input. Please contact your
technical supervisor.

SC Codes Group 2: Exposure

Polygon motor error: ON timeout
SC202
D
The polygon mirror motor does not reach the targeted operating speed within the
prescribed time.
• CIS defective
• Make sure CN210 and CN220 are connected firmly.
• Replace the CIS.
• CIS defective
1. Retry the gray balance adjustment.
2. If the machine does not recover, do the following steps.
• Turn off the machine.
• Make sure CN210 and CN220 are connected firmly.
• Turn on the machine.
3. If the machine does not recover, replace the CIS.