Ricoh V-C3 D081 Field Service Manual page 531

Table of Contents

Advertisement

No.
Display
06
Download Error E06
Power off/on
19
Download Error E19
Power off/on
20
Down Error E20
Power Off/On
21
Download Error E21
Power Off/On
22
Download Error E22
Module ID
Card No xx/xx
Error Description/Recovery
Controller ROM update error 6
CPU clock error occurred.
Recovery
• Turn the machine power off/on.
• Set controller DIPSW-1 to ON to force the machine to write to
ROM.
• If you cannot force the machine to write, replace the controller
board.
Controller ROM update error 7
Schedule data is unclear.
Recovery
• Software defective
System error 1 (+SC991)
The physical address could not be mapped due to defective software
or hardware.
Recovery
• Cycle the machine off/on and re-try
• Replace controller board
System error 2 (+SC991)
There was not sufficient memory to download.
Recovery
• Cycle the machine off/on and re-try.
• Replace RAM
• Replace the controller board
System error 3 (+SC991)
Data failed to decompress due to defective card.
Recovery
• Cycle the machine off/on and re-try.
• Replace card
• Replace controller board
Handling Errors
6
529

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-c3 d082

Table of Contents