Lockout Threshold
Sets a limit on the frequency of lockouts for account lockouts.
[1 to 10/5/1]
Cancellation On/Off
Determines whether the system waits the prescribed time for input of a correct user ID
and password after an account lockout has occurred.
[0 to 1/0/1]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct user ID and password are entered.
Cancellation Time
Determines the length of time that the system waits for correct input of the user ID and
password after a lockout has occurred. This setting is used only if SP5413-3 is set to
"1" (on).
[1 to 999/60/1 min.]
Access Mitigation
Mitigation On/Off
Switches on/off masking of continuously used IDs and passwords that are identical.
[0 to 1/0/1]
0: Off
1: On
Mitigation Time
Sets the length of time for excluding continuous access for identical user IDs and
passwords.
[0 to 60/15/1 min.]
Password Attack
Permissible Number
Sets the number of attempts to attack the system with random passwords to gain illegal
access to the system.
[0 to 100/30/1 attempt]