SC Codes Group 8: Overall System

3
SC816
D
150
Energy save I/O subsystem error
An error was detected in the signal from the ASIC (controller board) which controls
the STR (Suspend to RAM) function.
Note: STR is a feature of this machine that minimizes energy consumption while the
machine is in the energy saver mode.
• Reboot the machine.
• Replace the controller board.
SCS
SC816-5
Machine attempted to enter STR mode before engine was
OFF.
Sub System
SC816-39
Error occurred during system start up.
Hardware
SC816-50
Printer version only. Not used for this machine.
NCS (Network Control Service)
An error occurred in the access control port list:
SC816-67
Sub System
SC816-79
Message mismatch.
Hardware/System
SC816-90
A forced system reset (WDOG) occurred.
• Number of registrations exceeded 125
• Data notifications exceeded 12
• Data extension incorrect
GW