Repairs
Check the wheelchair to confirm the specified battery type.
If the wheelchair is equipped with 60 A batteries:
3. Disconnect the minus cable from the rear battery.
4. Disconnect the plus cable from the front battery.
5. Pull off the battery terminal covers from the cables.
NOTICE
Pre mounted cables
Replacement main circuit breakers are delivered with pre-mounted cables that
are tightened to the correct torque. Do not loosen, tighten or in any way adjust
the pre-mounted cables.
6. Remove the cables from all the attachments between the batteries
and the main circuit breaker. Note how they are attached for correct
reassembly.
7. Release the main circuit breaker by pulling out the small handle on
the right hand side. Pull it in direction B.
8. Set the replacement main circuit breaker to Off position. Note the
orientation of the new main circuit breaker with consideration to
subsequent assembly. The On/Off positions must agree with the
decal on the rear cover.
9. Pull out the small handle on the right hand side of the new main
circuit breaker and position it onto the holder. Fix it in correct
position by pushing in the small handle, direction A.
10. Mount the cables to their attachments.
11. Pull the terminal covers over the battery terminal connectors.
12. Reconnect the battery connection cables to the batteries.
13. Cover the battery terminals with the terminal covers.
14. Refit the chassis covers. See Covers , Page 14.
15. Switch the main circuit breaker to On; see fig. 244.

Seat

Remove and install seat with power seat tilt
The following tools are necessary for this task:
• Torque wrench.
• Allen socket, 3 mm.
80
Figure 245. Main circuit breaker release handle.
Figure 246. Battery connections relative to the battery
capacity.
Permobil M1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents