GE MiCOM P40 Technical Manual page 937

P446sv
Hide thumbs Also See for MiCOM P40:
Table of Contents

Advertisement

P446SV
ORDINAL
1368
Freq High
Freq High
1369
Freq Low
Freq Low
1370
Freq Not found
Freq Not found
1371
Stop Freq Track
Stop Freq Track
1372
3d/4th HarmonicA
3rd/4th Harmonic Restraint A Phase
1373
3d/4th HarmonicB
3rd/4th Harmonic Restraint B Phase
1374
3d/4th HarmonicC
3rd/4th Harmonic Restraint C Phase
1375
Teleprot Disturb
This is an output signal available in the PSL, that could be mapped to "C Diff Failure" for IEC870-5-103
1376
I>> Backup Super
This applies only if distance primary FUN is selected (in IEC870-5-103)
This signal is ON if an overcurrent stage is selected to be enabled on VTS and distance is blocked by VTS
1377
I> Trip by VTS
This applies only if distance primary FUN is selected (in IEC870-5-103)
This signal is ON if DDB 1376 is ON and one of the overcurrent stages set to be enabled on VTS condition trips
1378
Teleprot Tx
This applies only if distance primary FUN is selected (in IEC870-5-103)
This is an output signal available in the PSL, which could be mapped to a signal send of one of the two teleprotection channels
1379
Teleprot Rx
This applies only if distance primary FUN is selected (in IEC870-5-103)
This is an output signal available in the PSL, which could be mapped to a signal receive of one of the two teleprotection channels
1380
Group Warning
This is an output signal available in the PSL, which can be mapped in IEC870-5-103 to a minor defect which does not shut down the
main protection
1381
Group Alarm
This is an output signal available in the PSL, which can be mapped in IEC870-5-103 to a major problem normally linked to the
watchdog
1382
AR On Pulse
This is an output signal available in the PSL, which can be mapped to enable AR via pulse
1383
AR Off Pulse
This is an output signal available in the PSL, which can be mapped to disable AR via pulse
1384
AR Enable
External input via DDB mapped in PSL to enable AR if Enable AR CB1 or Enable AR CB2 is set and AR Configuration setting is enabled
1385
AR In Service
Auto-reclose in service
1386
MaxCh1 PropDelay
Setting MaxCh 1 PropDelay has been exceeded
1387
MaxCh2 PropDelay
Setting MaxCh 2 PropDelay has been exceeded
1390
ZV AN Comparator
ZV AN Comparator
1391
ZV BN Comparator
ZV BN Comparator
1392
ZV CN Comparator
ZV CN Comparator
1393
ZV AB Comparator
ZV AB Comparator
1394
ZV BC Comparator
ZV BC Comparator
1395
ZV CA Comparator
ZV CA Comparator
P446SV-TM-EN-1
SIGNAL NAME
DDB_FREQ_ABOVE_RANGE_LIMIT
DDB_FREQ_BELOW_RANGE_LIMIT
DDB_FREQ_NOT_FOUND
DDB_FREQ_STOP_TRACK
DDB_FOURTH_HARM_A
DDB_FOURTH_HARM_B
DDB_FOURTH_HARM_C
DDB_TELEPROTECTION_DISTURBED
DDB_BACK_UP_SUPERVISION
DDB_POC_TRIP_BY_VTS
DDB_TELEPROTECTION_SENT
DDB_TELEPROTECTION_RECEIVED
DDB_GROUP_WARNING
DDB_GROUP_ALARM
DDB_AR_ON_PULSE
DDB_AR_OFF_PULSE
DDB_AR_ENABLE
DDB_AR_IN_SERVICE
DDB_MAX_CH1_PROP_DELAY
DDB_MAX_CH2_PROP_DELAY
DDB_ZONE_V_AN_RAW
DDB_ZONE_V_BN_RAW
DDB_ZONE_V_CN_RAW
DDB_ZONE_V_AB_RAW
DDB_ZONE_V_BC_RAW
DDB_ZONE_V_CA_RAW
ELEMENT NAME
DESCRIPTION
Appendix B -Settings and Signals
B191

Advertisement

Table of Contents
loading

Table of Contents