Appendix B -Settings and Signals
ORDINAL
1026
LED 3
Programmable LED 3
1027
LED 4
Programmable LED 4
1028
LED 5
Programmable LED 5
1029
LED 6
Programmable LED 6
1030
LED 7
Programmable LED 7
1031
LED 8
Programmable LED 8
1070
LED Cond IN 1
Input to LED Output Condition
1071
LED Cond IN 2
Input to LED Output Condition
1072
LED Cond IN 3
Input to LED Output Condition
1073
LED Cond IN 4
Input to LED Output Condition
1074
LED Cond IN 5
Input to LED Output Condition
1075
LED Cond IN 6
Input to LED Output Condition
1076
LED Cond IN 7
Input to LED Output Condition
1077
LED Cond IN 8
Input to LED Output Condition
1106
CB1 I^ Maint
Broken current maintenance alarm - circuit breaker cumulative duty alarm set-point CB1
1107
CB1 I^ Lockout
Broken current lockout alarm - circuit breaker cumulative duty has been exceeded CB1
1108
No.CB1 OPs Maint
No of circuit breaker operations maintenance alarm - indicated due to circuit breaker trip operations threshold CB1
1109
No.CB1 OPs Lock
No of circuit breaker operations maintenance lockout - excessive number of circuit breaker trip operations, safety lockout CB1
1110
CB1 Time Maint
Excessive circuit breaker operating time maintenance alarm - excessive operation time alarm for the circuit breaker (slow
interruption time) CB1
1111
CB1 Time Lockout
Excessive circuit breaker operating time lockout alarm - excessive operation time alarm for the circuit breaker (too slow interruption)
CB1
1112
CB1FaultFreqLock
Excessive fault frequency lockout alarm CB1
1113
CB2 I^ Maint
Broken current maintenance alarm - circuit breaker cumulative duty alarm set-point CB2
1114
CB2 I^ Lockout
Broken current lockout alarm - circuit breaker cumulative duty has been exceeded CB2
1115
No.CB2 OPs Maint
No of circuit breaker operations maintenance alarm - indicated due to circuit breaker trip operations threshold CB2
1116
No.CB2 OPs Lock
No of circuit breaker operations maintenance lockout - excessive number of circuit breaker trip operations, safety lockout CB2
1117
CB2 Time Maint
Excessive circuit breaker operating time maintenance alarm - excessive operation time alarm for the circuit breaker (slow
interruption time) CB2
1118
CB2 Time Lockout
Excessive circuit breaker operating time lockout alarm - excessive operation time alarm for the circuit breaker (too slow interruption)
CB2
B182
SIGNAL NAME
DDB_OUTPUT_LED_3
DDB_OUTPUT_LED_4
DDB_OUTPUT_LED_5
DDB_OUTPUT_LED_6
DDB_OUTPUT_LED_7
DDB_OUTPUT_LED_8
DDB_LED_CON_1
DDB_LED_CON_2
DDB_LED_CON_3
DDB_LED_CON_4
DDB_LED_CON_5
DDB_LED_CON_6
DDB_LED_CON_7
DDB_LED_CON_8
DDB_BROKEN_CURRENT_ALARM
DDB_BROKEN_CURRENT_LOCKOUT
DDB_MAINTENANCE_ALARM
DDB_MAINTENANCE_LOCKOUT
DDB_EXCESSIVE_OP_TIME_ALARM
DDB_EXCESSIVE_OP_TIME_LOCKOUT
DDB_EFF_LOCKOUT
DDB_BROKEN_CURRENT_ALARM_2
DDB_BROKEN_CURRENT_LOCKOUT_2
DDB_MAINTENANCE_ALARM_2
DDB_MAINTENANCE_LOCKOUT_2
DDB_EXCESSIVE_OP_TIME_ALARM_2
DDB_EXCESSIVE_OP_TIME_LOCKOUT_2
ELEMENT NAME
DESCRIPTION
P446SV
P446SV-TM-EN-1