GE MiCOM P40 Technical Manual page 786

P446sv
Hide thumbs Also See for MiCOM P40:
Table of Contents

Advertisement

Appendix B -Settings and Signals
MENU TEXT
Any of the digital channels may be selected to trigger the disturbance recorder on either a low to high or a high to low transition.
Digital Input 6
The digital channels may monitor any of the opto isolated inputs or output contacts, in addition to a number of internal relay digital signals,
such as protection starts, LEDs etc.
Input 6 Trigger
Any of the digital channels may be selected to trigger the disturbance recorder on either a low to high or a high to low transition.
Digital Input 7
The digital channels may monitor any of the opto isolated inputs or output contacts, in addition to a number of internal relay digital signals,
such as protection starts, LEDs etc.
Input 7 Trigger
Any of the digital channels may be selected to trigger the disturbance recorder on either a low to high or a high to low transition.
Digital Input 8
The digital channels may monitor any of the opto isolated inputs or output contacts, in addition to a number of internal relay digital signals,
such as protection starts, LEDs etc.
Input 8 Trigger
Any of the digital channels may be selected to trigger the disturbance recorder on either a low to high or a high to low transition.
Digital Input 9
The digital channels may monitor any of the opto isolated inputs or output contacts, in addition to a number of internal relay digital signals,
such as protection starts, LEDs etc.
Input 9 Trigger
Any of the digital channels may be selected to trigger the disturbance recorder on either a low to high or a high to low transition.
Digital Input 10
The digital channels may monitor any of the opto isolated inputs or output contacts, in addition to a number of internal relay digital signals,
such as protection starts, LEDs etc.
Input 10 Trigger
Any of the digital channels may be selected to trigger the disturbance recorder on either a low to high or a high to low transition.
Digital Input 11
The digital channels may monitor any of the opto isolated inputs or output contacts, in addition to a number of internal relay digital signals,
such as protection starts, LEDs etc.
Input 11 Trigger
Any of the digital channels may be selected to trigger the disturbance recorder on either a low to high or a high to low transition.
Digital Input 12
The digital channels may monitor any of the opto isolated inputs or output contacts, in addition to a number of internal relay digital signals,
such as protection starts, LEDs etc.
Input 12 Trigger
B40
COL
ROW
DEFAULT SETTING
0C
16
Relay 6
0C
17
No Trigger
0C
18
Relay 7
0C
19
No Trigger
0C
1A
Relay 8
0C
1B
No Trigger
0C
1C
Relay 9
0C
1D
No Trigger
0C
1E
Relay 10
0C
1F
No Trigger
0C
20
Relay 11
0C
21
No Trigger
0C
22
Relay 12
0C
23
No Trigger
DESCRIPTION
See Data Type G32 in Menus Database
[Indexed String]
No Trigger
Trigger L/H
Trigger H/L
[Indexed String]
See Data Type G32 in Menus Database
[Indexed String]
No Trigger
Trigger L/H
Trigger H/L
[Indexed String]
See Data Type G32 in Menus Database
[Indexed String]
No Trigger
Trigger L/H
Trigger H/L
[Indexed String]
See Data Type G32 in Menus Database
[Indexed String]
No Trigger
Trigger L/H
Trigger H/L
[Indexed String]
See Data Type G32 in Menus Database
[Indexed String]
No Trigger
Trigger L/H
Trigger H/L
[Indexed String]
See Data Type G32 in Menus Database
[Indexed String]
No Trigger
Trigger L/H
Trigger H/L
[Indexed String]
See Data Type G32 in Menus Database
[Indexed String]
No Trigger
AVAILABLE OPTIONS
P446SV-TM-EN-1
P446SV