Front Panel Operation
CDM-760 Advanced High-Speed Trunking Modem
To change the DPD Min or Max Search Delay: Use the arrow keys to toggle between the
minimum or maximum delay value, and then use the arrow keys to edit that value. Press
ENTER.
If DPD is being bench-tested with two units in a back-to-back configuration, the
minimum delay should be set to 0 ms, and the maximum to 20 ms. This takes into
account the lack of satellite delay.
6.2.2.8
(CONFIG:) Comp
K4 GZip Lossless Compression and Decompression is an optional feature that requires
installation of the Compression Card in the modem.
Compression: Disabled
Decompression: Disabled
Use the arrow keys to select Compression or Decompression. For either, use the
arrow keys to select operation as Disabled or Enabled. Press ENTER.
6.2.2.9
(CONFIG:) Remote
Remote Control=Serial+Ethernet
Use the arrow keys to select Remote Control or InBand. Press ENTER.
6.2.2.9.1 (CONFIG: Remote) Remote Control
Use the arrow keys to select a parameter. Press ENTER.
(CONFIG: Remote) Remote Control Local
Select Local to limit monitor and control (M&C) of the unit only to the modem front panel.
Local control (front panel operation) is always available, regardless of which setting is
selected on this menu.
(CONFIG: Remote) Remote Control Serial or Ser+Ethernet
Interface= RS-485-2W
Address= 0001
•
Select Serial to allow EIA-232/485 or Telnet remote access to the modem.
•
Select Ser+Ethernet (Serial+Ethernet) to allow all methods of remote access to the modem.
•
Use the arrow keys to select Interface, Address, or (Baud rate). Press ENTER. Then:
Inband=Disable
6–44
()
(232,485-2,485-4)
38400 baud
()
Revision 4
MN-CDM760