Utility:) Circuit Id - Comtech EF Data CDM-760 Installation And Operation Manual

Advanced high-speed trunking modem
Table of Contents

Advertisement

Front Panel Operation
CDM-760 Advanced High-Speed Trunking Modem
Message
This Unit is in Standby (1:1 only)
Press ENTER key to force Unit
into Standby (1:1 only)
Press ENTER or CLEAR to return to the previous menu.
(Utility: 1:1) Status
1:1 Redundancy Status:
1:1 Switch=Not Connected
This read-only screen displays the status of the 1:1 switch connection:
Message
Not Connected
Connected Offline
Connected Online
Press ENTER or CLEAR to return to the previous menu.
6.2.6.6
(Utility:) 1:N
1:N Redundancy: Disabled
Use the  arrow keys to select 1:N Redundancy as Enabled or Disabled. Press ENTER
If the unit is connected to a Comtech EF Data CRS-500 M:N Redundancy System (as
part of a 1:N system), this setting must set to Enabled. In all other circumstances (i.e.,
standalone operation or 1:1 Redundancy), 1:N Redundancy must be set to Disabled.
6.2.6.7

(Utility:) Circuit ID

Edit this Modem's Circuit ID:
------------------------
You may create a Circuit ID string, up to a maximum length of 24 characters, on the bottom line
of this display.
Description
This message indicates that, while this modem is properly connected to a
supported 1:1 redundancy switch, it is the Offline (standby) unit of the 1:1
pair at present and it cannot be "forced" into the Online position. You can
only "force" a switch of the Online modem into the Offline (Standby)
position.
This message indicates that this modem is connected to a 1:1 switch and
the modem is Online. Press ENTER to force this modem Offline and bring
the Standby modem Online.
Description
The modem is either not connected to a supported 1:1 switch, or the connection is faulty.
The modem is connected to a supported 1:1 switch and is in the "Offline" state.
The modem is connected to a supported 1:1 switch and is in the "Online" state.
6–70
Revision 4
MN-CDM760
.
()