Technical Data - Siemens SINUMERIK 840Di Manual

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

06.03
2.2.5

Technical Data

 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
Safety
Degree of protection
Class of protection
Safety regulations
Certifications
Power consumption
Typically
Max.
Mechanical data
Dimensions
Weight
Climatic environmental conditions
Heat dissipation
Temperature limit values
– MCI board alone
– MCI board in PCU 50
Tested to
Limit values of rel. humidity
Tested to
Temperature change
Condensation
Quality assurance
Vibrational load during operation
Class
Frequency range
Const. excursion/acceleration
Tested to
– module in PCU 50
Shock load during operation
Acceleration
Duration of nominal shock
Tested to
– module in PCU 50
Notice
The specified safety regulations, certifications, degree of protection and class
of protection only apply for the case that the module is plugged in a
SINUMERIK PCU 50.
2 Hardware Descriptions
IP 20
Class of protection I, acc. to VDE 0106 P1:
1982 (IEC 536)
EN61131-1
CE, UL, CSA
5V
4.7W
6W
PCI card, 2/3 length
198g
Open-circuit cooling
Operation
Storage/transportation
°C
5 ... 55
DIN IEC 68-2-1, DIN IEC 68-2-2
(DIN EN 60068-2-2), DIN IEC 68-2-14
5 ... .80%
DIN IEC 68-2-30
per min.
max. 1K
not admissible
acc. to ISO 9001
3M4
10 ... 58Hz/58... 200Hz
0.075mm / 1g
DIN EN 60068-2-6
2
50m/sec
30msecs
DIN EN 60068-2-6
2.2 MCI board
3.3V
50mW
200mW
°C
–40 ... 70
°C
–20 ... 60
5 ... .95%
per hour
max. 10K
2-55