2 Hardware Descriptions
2.7 SINUMERIK Industrial PC
Options
References
(SW 2.2 and
higher)
2-82
S
Robust design (continuous operation, high noise immunity)
S
Space-saving installation thanks to compact dimensions (LxWxH):
296x267x100mm
S
Easy installation with four screws on the rear of the operator panel front
S
Mounting position and location to a large degree variable
S
Screen resolution
S
Power supply:
S
Interfaces:
– Parallel interface LPT1
– Serial interfaces 1 x RS-232-C (25–pole), 1 x RS–232–C (9–pole)
– PS/2 keyboard interface
– PS/2 mouse interface
– MPI/PROFIBUS DP (max. 12 Mbaud)
– VGA interface for external monitor
– Ethernet connection 10/100 Mbaud
– Interfaces to the operator panel:
LVDS interface for SINUMERIK-OP,
USB interface for SINUMERIK-OP (internal)
– USB interfaces:
with Pentium II/III 366/500MHz: 1 x USB interface
with Celeron 566MHz/1.2GHz: 2 x USB interfaces
S
Expansion slots
– 1 PCI expansion slot (length: max. 265mm, occupied by the MCI board)
– 1 x shared ISA/PCI expansion slot (length: max. 175mm, occupied with
option MCI board extension and MCI board extension slot variant).
The following options are offered:
S
External floppy disk drive
S
Memory extension up to max. 512MB.
The complete documentation on the PCU 50 is to be found in:
References:
/BH/ Operator Components Manual
Component PCU 50.
In SW 2.2 and higher, distributed connection of PCU and operator panel is pos-
sible via Videolink (option).
References:
/BH/ Operator Components Manual
Distributed configuration
640x480 (VGA), up to 1024x768 (XGA)
24VDC