06.03
PROFIBUS DP
(X2)
PROFIBUS
address (S1)
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
Interface description of the PROFIBUS DP interface (X2):
S
Connection:
9-pin SUB-D socket connector
S
Pin assignment.
Table 2-17
Pin assignment: PROFIBUS DP (X2)
Pin
Designation
1
2
3
RxD/TxD-P
4
RTS
5
DGND
6
VP
7
8
RxD/TxD-N
9
1) VO Voltage Output
O
Output
B
Bi-directional
S
Connector
– 6ES7972-0BA40-0XA0; cable outlet 35
– 6ES7972-0BB40-0XA0; cable outlet 35
– 6ES7972-0BA11-0XA0; cable outlet 90
– 6ES7972-0BB11-0XA0; cable outlet 90
S
Cables:
– 6XV1830-0EH10; by the meter, non-trailable
– 6XV1830-3BH10; by the meter, trailable
S
Further technical data
Maximum possible data transmission rate: 12 Mbit/sec.
The PROFIBUS address of the ADI4 can be set in the range 1 to 127 using
switch S1.
Table 2-18
Meaning of switch S1
Switch
Meaning
1
PROFIBUS address:
2
PROFIBUS address:
3
PROFIBUS address:
4
PROFIBUS address:
5
PROFIBUS address:
6
PROFIBUS address:
7
PROFIBUS address:
8
not used
Notice
A newly set PROFIBUS address will only come into effect after power ON.
2 Hardware Descriptions
2.12 I/O Module PP72/48
Type
Function
1)
B
Receive/transmit data P (B line)
O
Request to Send
VO
Data reference potential (M5V)
VO
Power supply voltage plus (P5V)
B
Receive/transmit data N (A line)
0
, without PG socket connector
0
, with PG socket connector
0
, without PG socket connector
0
, with PG socket connector
0
2
= 1
1
2
= 2
2
2
= 4
3
2
= 8
4
2
= 16
5
2
= 32
6
2
= 64
2-95