Siemens SINUMERIK 840Di Manual page 385

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

06.03
Machine data
Number of
input bytes
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
ET200 I/Os: IM 153
Slot
Module
4
SM 322 DO16xDC24V/0.5A
5
SM 322 DO32xDC24V/0.5A
6
SM 321 DI16xDC24V/0.5A
7
SM 321 DI32xDC24V/0.5A
ADI4
Slot
Module
4
Drive modules
5
Drive modules
6
Drive modules
7
Drive modules
8
Drive modules
9
Drive modules
10
Drive modules
11
Drive modules
12
Drive modules
13
Drive modules
14
Drive modules
15
Drive modules
16
Drive modules
17
Drive modules
18
Drive modules
19
Drive modules
20
Drive modules
21
Drive modules
22
Drive modules
Note:
The structure of the PROFIBUS message frame is described in Subsection 7.3.6,
page 7-220f.
Parameterization of the NC machine data is shown below:
ET200
3 input bytes
ADI4
1 input byte.
Note
Although only four input bytes are used, five must be declared. The 1st input
byte is always assigned to the MCI board extension module, even if it does not
exist:
– MD10350: FASTIO_DIG_NUM_INPUTS = 5
10 NC Start-Up with HMI Advanced
10.6 Digital and analog I/O devices
I address
O address
128...129
130...133
128...129
130...133
I address
O address
258...275
258...267
332...349
332...341
350...367
350...359
312...329
312...321
330...331
330...331
Comment
Comment
1. Axis
1. Axis
2nd Axis
2nd Axis
3rd Axis
3rd Axis
4th Axis
4th Axis
I word
O word
10-385