Setting Parameters For Simodrive Drives - Siemens SINUMERIK 840Di Manual

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

16 840Di Specific Data and Functions
16.3 Travel to fixed stop with high-resolution torque reduction (SW 2.2 and higher)
16.3.3

Setting parameters for SIMODRIVE drives

The requirements for an automatic or manual adjustment of the following SIMODRIVE drives:
are met with SW 4.1 and higher.
The following describes the function on the basis of a SIMODRIVE 611 universal (DP slave 611U)
drive. Please adapt your procedure for the other SIMODRIVE drives.
Parameter P0881
Scaling
Examples for other resolutions:
Setpoint torque
T
set
T
:
max
Maximum possible drive torque from rated motor torque and parameter P1230 Torque limit value.
TorRed:
The percent specified via FXST for the reduced drive (control word in SIMODRIVE standard mes-
sage frame 102 to 107).
16.3.4
Setting parameters for the SINUMERIK 840Di NC
In the SINUMERIK 840Di NC system, the parameters for the resolution of the torque reduction are
set via the axis-specific machine data:
16-512
– SIMODRIVE 611 universal/universal E
– SIMODRIVE POSMO CD/CA
– SIMODRIVE POSMO SI.
Note
If third-party drives are used, please read the manufacturer's documentation to
see whether and how to set the parameters on the drive.
The resolution of the torque reduction is parameterized in the DP slave 611U in
parameter:
S
P0881 Torque reduction evaluation
As standard, in the DP slave parameter P0881 is scaled to: 16384.00 ¢ 1%
– 1638.40 ¢ 0.1%
¢ 0.01%.
– 163.84
Setpoint torque T
of the drive is therefore calculated by:
set
T
= T
set
max
S
MD 37620: PROFIBUS_TORQUE_RED_RESOL (torque reduction resolu-
tion on PROFIBUS (LSB weighting)).
P0881 * TorRed[%]
* ( 1 –
16384 * 100%
 Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
06.03
)

Advertisement