Alcatel-Lucent 7450 Quality Of Service Manual page 731

Ethernet service switch; service router; extensible routing system
Hide thumbs Also See for 7450:
Table of Contents

Advertisement

create — The create keyword is required if creating a new named pool within the policy when the
amber-alarm-threshold
Syntax
amber-alarm-threshold percentage
no amber-alarm-threshold
Context
config>qos>named-pool-policy>q1-pools>pool
Description
This command configures the threshold for the amber alarm on the over-subscription allowed.
Users can selectively enable amber or red alarm thresholds. But if both are enabled (non-zero) then the
red alarm threshold must be greater than the amber alarm threshold.
The no form of the command reverts to the default value.
Default
0
Parameters
percentage — Specifies the amber alarm threshold.
red-alarm-threshold
Syntax
red-alarm-threshold percentage
no red-alarm-threshold
Context
config>qos>named-pool-policy>q1-pools>pool
Description
This command configures the threshold for the red alarm on the over-subscription allowed.
Users can selectively enable amber or red alarm thresholds. But if both are enabled (non-zero) then the
red alarm threshold must be greater than the amber alarm threshold.
The no form of the command reverts to the default value.
Default
0
Parameters
percentage — Specifies the amber alarm threshold.
Quality of Service Guide
system is configured to require the explicit use of the keyword to prevent accidental object
creation. Objects may be accidentally created when this protection is disabled and an object
name is mistyped when attempting to edit the object. This keyword is not required when the
protection is disabled. The keyword is ignored when the named pool already exists within the
policy.
Values
1 to 1000
Values
1 to 1000
Named Pools
733

Advertisement

Table of Contents
loading

This manual is also suitable for:

79507750

Table of Contents