◆ b: Application

Application parameters configure the source of the Up/Down command, timer functions, the Dwell function, the Droop
Control function, Energy Savings, and a variety of other application-related settings.
b1: Operation Mode Selection
No.(Addr.)
Name
b1-01
Speed Reference Selection
(180H)
b1-02
Up/Down Command Selection
(181H)
b1-03
Stopping Method Selection
(182H)
b1-06
Digital Input Reading
(185H)
b1-08
Up/Down Command Selection
(187H)
while in Programming Mode
b1-14
Phase Order Selection
(1C3H)
b2: Magnetic Flux Compensation
No.(Addr.)
Name
b2-08
Magnetic Flux Compensation
(190H)
Value
b4: Delay Timers
No.(Addr.)
Name
b4-01
Timer Function On-Delay Time
(1A3H)
b4-02
Timer Function Off-Delay Time
(1A4H)
b6: Dwell Function
No.(Addr.)
Name
b6-01
Dwell Speed at Start
(1B6H)
b6-02
Dwell Time at Start
(1B7H)
b6-03
Dwell Speed at Stop
(1B8H)
b6-04
Dwell Time at Stop
(1B9H)
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
All Modes
0: Digital operator
1: Analog input terminals
2: MEMOBUS/Modbus communications
3: Option card
All Modes
0: Digital operator
1: Digital input terminals
2: MEMOBUS/Modbus communications
3: Option card
All Modes
0: Ramp to stop
1: Coast to stop
4: Elevator Emergency Stop
Note: Setting 4 is available in the control mode CLV or CLV/PM for drives with software
versions PRG: 7017 or later. The setting is 0 or 1 for software version PRG: 7016.
All Modes
0: Input status is read once and processed immediately (for quick response).
1: Input is read twice and processed only if the status is the same in both readings (robust
against noisy signals).
All Modes
0: Up/Down command not accepted while in the Programming Mode.
1: Up/Down command accepted while in the Programming Mode.
2: Prohibit entering Programming Mode during run.
All Modes
0: U-V-W
1: U-W-V
Description
V/f
OLV
Sets the magnetic flux compensation as a percentage of the no-load current value (E2-03).
Description
All Modes
Used to set the on-delay and off-delay times for a digital timer output (H2- = 12). The
output is triggered by a digital input programmed to H1- = 18).
Description
All Modes
Parameters b6-01 and b6-02 set the speed to hold and the time to maintain that speed at start.
Parameters b6-03 and b6-04 set the speed to hold and the time to maintain that speed at stop.
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
TMonly
Default: 0
Min: 0
166
Max: 3
common_
TMonly
Default: 1
Min: 0
167
Max: 3
common_
TMonly
Default: 0
Min: 0
167
Max: 4
common_
TMonly
Default: 1
Min: 0
168
Max: 1
common_
TMonly
Default: 0
Min: 0
168
Max: 2
common_
Default: 0
TMonly
Min: 0
168
Max: 1
Setting
Page
Default: 0%
common_
TMonly
Min: 0%
169
Max: 1000%
Setting
Page
Default: 0.0 s
Min: 0.0 s
169
common_
Max: 3000.0 s
TMonly
Default: 0.0 s
Min: 0.0 s
169
Max: 3000.0 s
Setting
Page
Default: 0.0%
Min: 0.0%
170
Max: 100.0%
Default: 0.0 s
Min: 0.0 s
170
common_
Max: 10.0 s
TMonly
Default: 0.0%
Min: 0.0%
170
Max: 100.0%
Default: 0.0 s
Min: 0.0 s
170
Max: 10.0 s
B
395