YASKAWA L1000A Technical Manual page 247

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

n8-02: Pole Attraction Current
Sets the pull-in current used to detect rotor position. This setting rarely needs to be changed.
No.
n8-02
n8-35: Initial Rotor Position Detection Selection
Selects how the rotor position is detected at start.
No.
n8-35
Setting 1: High Frequency Injection
High frequency is injected in order to detect the rotor position. Some noise may be generated from the motor at start.
Setting 2: Pulse injection
A pulse signal is injected into the motor in order to detect the rotor position.
n8-36: High Frequency Injection Level
Sets the frequency level used for High Frequency Injection.
No.
n8-36
n8-37: High Frequency Injection Amplitude
Sets the amplitude for High Frequency Injection as a percentage of the voltage (200 V or 400 V or 575 V).
No.
n8-37
n8-81: High Frequency Injection during Rescue Operation
Sets the frequency used for High Frequency Injection during Rescue Operation.
No.
n8-81
n8-82: High Frequency Injection Amplitude during Rescue Operation
Sets the amplitude for High Frequency Injection during Rescue Operation as a percentage of the voltage (200 V or 400 V
or 575 V).
No.
n8-82
High Frequency Injection Amplitude during Rescue Operation
n8-84: Polarity Detection Current
Sets the current level (E5-03) as a percentage for detecting polarity during Initial Polarity Estimation.
No.
n8-84
n8-86: Magnet Pole Search Error Detection Selection
Enables fault detection for Initial Polarity Estimation (dv8).
No.
n8-86
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Parameter Name
Pole Attraction Current
Parameter Name
Initial Rotor Position Detection Selection
Parameter Name
High Frequency Injection
Parameter Name
High Frequency Injection Amplitude
Parameter Name
High Frequency Injection during Rescue Operation
Parameter Name
Parameter Name
Polarity Detection Current
Parameter Name
Magnet Pole Search Error Detection Selection
5.9 n: Special Adjustments
Setting Range
Default
0 to 150%
Setting Range
Default
1 or 2
Setting Range
Default
25 to 1000 Hz
500 Hz
Setting Range
Default
0.0 to 99.9%
20.0%
Setting Range
Default
25 to 1000 Hz
90 Hz
Setting Range
Default
0.1 to 99.9%
15.0%
Setting Range
Default
0 to 150%
100%
Setting Range
Default
0 or 1
80%
1
5
0
247