5.10 o: Operator Related Settings
o1-04: V/f Pattern Setting Units
Determines the units used for the frequency reference when setting parameters that create the V/f pattern: E1-04, E1-06,
E1-09, E1-11, and E2-04. For motor 2, this includes parameters E3-04, E3-06, E3-07, E3-09, and E4-04.
Enabled only in vector control modes (CLV and CLV/PM).
No.
o1-04
Setting 0: Hz
Setting 1: r/min
Note:
For motor 2, o1-04 can only be set to 0 for Hertz.
o1-05: LCD Contrast Control
Sets the brightness of the LCD operator (option). Lower the setting to make the LCD brighter or raise the setting to make
the LCD darker.
No.
o1-05
<1>
<1> Available in drive software versions PRG: 7200 or later.
o1-06: User Monitor Selection Mode
Note: Available in drive software PRG: 7017 or later.
The digital operator display monitors shown directly below the active monitor are the next two sequential monitors. If
o1-06 (User Monitor Selection Mode) is set to "1: 3 Monitor Selectable", those two monitors are locked as specified by
parameters o1-07 and o1-08 and will not change as the top parameter is scrolled with the Up/Down Arrow keys.
No.
o1-06
Setting 0: 3 Monitor Sequential (Displays the next 2 sequential monitors)
Setting 1: 3 Monitor Selectable (o1-07, and o1-08 selected monitor is displayed)
o1-07: Second Line Monitor Selection
Note: Available in drive software PRG: 7017 or later.
For example, set "104" to display monitor parameter U1-04.
Selects the monitor displayed on the second line. The monitor parameter number is entered into the spaces provided:
U-.
Some monitors are only available in certain control modes.
No.
o1-07
o1-08: Third Line Monitor Selection
Note: Available in drive software PRG: 7017 or later.
For example, set "104" to display monitor parameter U1-04.
Selects the monitor displayed on the third line. The monitor parameter number is entered into the spaces provided:
U-.
Some monitors are only available in certain control modes.
No.
o1-08
250
Parameter Name
V/f Pattern Setting Units
Parameter Name
LCD Contrast Control
Parameter Name
User Monitor Selection Mode
Parameter Name
Second Line Monitor Selection
Parameter Name
Third Line Monitor Selection
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Setting Range
0 or 1
Setting Range
0 to 5
Setting Range
0, 1
Setting Range
101 to 699
U1-01 (Speed Reference) to
U6-99 (Option Monitor 20)
Setting Range
101 to 699
U1-01 (Speed Reference) to
U6-99 (Option Monitor 20)
Default
Determined by A1-02
Default
3
Default
0
Default
102
Default
103