B.3 Parameter Table
H1-
Function
Setting
56
Motor Contactor Feedback
57
High Speed Limit (Up)
58
High Speed Limit (Down)
5A
Motor Contactor Feedback 2
<44>
5B
Brake Feedback 2
<44>
5C
Floor Sensor
67
Communications Test Mode
79
Brake Feedback
<44> Available in drive software versions PRG: 7017 or later.
H2: Multi-Function Digital Outputs
No.(Addr.)
Name
H2-01
Terminals M1-M2 Function
(40BH)
Selection (relay)
H2-02
Terminals M3-M4 Function
(40CH)
Selection (relay)
H2-03
Terminals M5-M6 Function
(40DH)
Selection (relay)
H2-04
Terminal P1-C1 Function
(40EH)
Selection (photocoupler)
H2-05
Terminal P2-C2 Function
(40FH)
Selection (photocoupler)
H2-
Function
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-set Speed Agree 1
4
Speed Detection 1
410
H1 Multi-Function Digital Input Settings
All Modes
Open: Motor contactor open
Closed: Motor contactor closed (N.O.)
All Modes
Closed: Uses the leveling speed as the maximum speed when going up.
All Modes
Closed: Uses the leveling speed as the maximum speed when going down.
All Modes
Open: Motor contactor closed (N.C.)
Closed: Motor contactor open
All Modes
Open: Brake open (N.C.)
Closed: Brake closed
V/f
OLV
Closed: Initiate Direct Landing (S5-10 = 1)
All Modes
Tests the MEMOBUS/Modbus RS-485/422 interface. Displays "PASS" if the test completes successfully.
All Modes
Open: Brake closed
Closed: Brake open (N.O.)
All Modes
Refer to
H2 Multi-Function Digital Output Settings on page 410
values.
H2 Multi-Function Digital Output Settings
All Modes
Closed: An Up/Down command is active or voltage is output.
All Modes
Open: Output speed is greater than the value of E1-09 (Minimum Output Frequency) or S1-01 (Zero Speed Level at
Stop).
Closed: Output frequency is less than or equal to the value of E1-09 (Minimum Output Frequency) or S1-01 (Zero
Speed Level at Stop).
All Modes
Closed: Output speed equals the speed reference (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output speed and speed reference equal L4-01 (plus or minus the hysteresis set to L4-02).
All Modes
Closed: Output speed is less than or equal to the value in L4-01 with hysteresis determined by L4-02.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
CLV
CLV/PM
Description
for a description of setting
Description
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
Setting
Default: 50
Min: 0
Max: 161
Default: 51
Min: 0
Max: 161
common_
Default: 6
TMonly
Min: 0
Max: 161
Default: 37
Min: 0
Max: 161
Default: F
Min: 0
Max: 161
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
Page
207
207
207
207
207
207
207
207
Page
208
208
208
208
208
Page
208
208
209
209
210