YASKAWA L1000A Technical Manual page 224

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

5.8 L: Protection Functions
Setting 2: Drive dedicated motor (speed range for constant torque: 1:10)
Use this setting when operating a drive duty motor that allows constant torque in a speed range of 1:10. The drive will
allow the motor to run with 100% load from 10% up to 100% speed. Running at slower speeds with full load can trigger
an overload fault.
Overload Tolerance
150
Rated Speed=100% Speed
60 s
A: Max. speed for 200LJ and above
B: Max. speed for 160MJ to 180 LJ
100
C: Max. speed for 132MJ and below
55
50
A
Continuous
0
110
100120 167 200
Speed (%)
Setting 3: Vector motor (speed range for constant torque: 1:100)
Use this setting when operating a drive-dedicated motor that allows constant torque in a speed range of 1:100. This motor
type is allowed to run with 100% load from 1% up to 100% speed. Running slower speeds with full load can trigger an
overload fault.
Overload Tolerance
150
Rated Speed=100% Speed
A: Max. speed for 200LJ and above
60 s
B: Max. speed for 160MJ to 180 LJ
C: Max. speed for 132MJ and below
100
90
Continuous
50
A
0 1
100120 167 200
Speed (%)
Setting 5: Constant torque PM motors (constant torque range of 1:500)
Sets protection characteristics needed when driving a PM with constant torque. These motors allow for a speed control
from 0.2% to 100% when operating with 100% load. Slower speeds with 100% load will trigger overload.
Overload Tolerance
Instantaneous rating (60 s)
150
125
115
100
83
77
67
0 0.2
Percent of base speed (%)
224
B
C
B
C
100
120
130
150
Cooling Ability
Motor is designed to effectively cool itself even at
low speeds.
Cooling Ability
Motor is designed to effectively cool itself at
ultra-low speeds.
Cooling Ability
Motor is designed to effectively cool itself at
ultra-low speeds (about 0.2% of base speed).
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Overload Characteristics
Continuous operation with 100% load from 5 Hz to
50 Hz.
Overload Characteristics
Continuous operation with 100% load from 0.5 Hz to
50 Hz.
Overload Characteristics
Continuous operation with 100% load from 0.2% to
100% of base speed.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents