B.3 Parameter Table
No. (Addr.)
Name
o1-20
Traction Sheave Diameter
(575H)
o1-21
Roping Ratio
(576H)
o1-22
Mechanical Gear Ratio
(577H)
o1-23
(174H)
HBB Non Display Select
<45>
<5> Default setting is determined by the control mode (A1-02).
<20> This parameter appears when the drive displays user-set units (o1-03 = 3).
<21> The control mode determines the selections available. In V/f Control, only settings 1 through 3 are permitted.
<38> Default setting and setting range changes when inches are selected for the length units (o1-12 = 1). The setting range becomes 3.70 to 78.00
inches, and the default becomes 15.70 inches.
<44> Available in drive software versions PRG: 7017 or later.
<45> Available in drive software versions PRG: 7200 or later.
<46> The setting range changes depending on drive software versions.
PRG: 7017 or earlier: 0.10 to 50.00
PRG: 7200 or later: 0.10 to 100.00
o2: Digital Operator Keypad Functions
No. (Addr.)
Name
o2-01
LO/RE Key Function Selection
(505H)
o2-02
STOP Key Function Selection
(506H)
o2-03
User Parameter Default Value
(507H)
o2-04
(508H)
Drive Model Selection
<1>
o2-05
Speed Reference Setting Method
(509H)
Selection
o2-06
Operation Selection when Digital
(50AH)
Operator is Disconnected
o2-09
Reserved
(50DH)
<1> Parameter setting value is not reset to the default value when the drive is initialized.
422
V/f
OLV
Sets the traction sheave diameter for display unit calculations.
V/f
OLV
Sets the roping ratio.
1: 1:1
2: 1:2
3: 1:3
4: 1:4
V/f
OLV
Sets the ratio of the gear installed for display unit calculations.
All Modes
Shows or hides the HBB command on the digital operator while the safety signal is being input.
0: Shows HBB
1: Hide HBB
All Modes
0: Disabled
1: Enabled. LO/RE key switches between LOCAL and REMOTE operation.
All Modes
0: Disabled. STOP key is disabled in REMOTE operation.
1: Enabled. STOP key is always enabled.
All Modes
0: No change.
1: Set defaults. Saves parameter settings as default values for a User Initialization.
2: Clear all. Clears the default settings that have been saved for a User Initialization.
All Modes
Enter the drive model. Setting required only if installing a new control board.
All Modes
0: ENTER key must be pressed to enter a speed reference.
1: ENTER key is not required. The speed reference can be adjusted using the up and down
arrow keys only.
All Modes
0: The drive continues operating if the digital operator is disconnected.
1: A fault is triggered (oPr) and the motor coasts to stop.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
Description
Setting
Default: 400 mm
<38>
common_
TMonly
Min: 100 mm
Max: 2000 mm
<38>
common_
TMonly
Default: 2
Min: 1
Max: 4
Default:
<5>
common_
TMonly
Min: 0.10
Max:
<46>
common_
TMonly
Default: 0
Min: 0
Max: 1
Setting
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 0
Min: 0
Max: 2
Default: Determined by
common_
drive capacity
TMonly
Min: –
Max: –
common_
TMonly
Default: 0
Min: 0
Max: 1
common_
Default: 0
TMonly
Min: 0
Max: 1
Page
251
251
252
252
Page
252
252
253
253