5.11 S: Elevator Parameters
Leveling Speed
Input Timing
(The speed is 40% of the nominal speed or more.)
Operating
speed
0
H1-
= 53
(Leveling Speed)
During
acceleration
(The speed is less than 40% of the nominal speed.)
Operating
speed
0
H1-
= 53
(Leveling Speed)
(The speed is 40% of the nominal speed or more.)
Operating
speed
0
H1-
= 53
Constant speed
(Leveling Speed)
operation at
less than the
(The speed is less than 40% of the nominal speed.)
rated speed
Operating
speed
0
H1-
= 53
(Leveling Speed)
Before start
<1> The drive will recognize the speed reference that is lower than the Leveling Speed Detection Level (d1-28) as the leveling speed if the speed
priority is set for multi-step speed reference (d1-18
268
Short Floor
ON(close)
<1>
ON(close)
<1>
ON(close)
<1>
ON(close)
<1>
=
0 or 3).
(The speed is over Optimum Speed.)
d1-19
Operating
(Nominal Speed)
speed
40% of nominal
speed
d1-26
(Leveling Speed)
Time
H1-
= 53
(Leveling Speed)
(The speed is optimal speed or less.)
Operating
d1-19
speed
(Nominal Speed)
40% of nominal
speed
d1-26
(Leveling Speed)
Time
H1-
= 53
(Leveling Speed)
d1-19
(Nominal Speed)
40% of nominal
speed
d1-26
(Leveling Speed)
Time
d1-19
(Nominal Speed)
40% of nominal
speed
d1-26
(Leveling Speed)
Time
Operates at the leveling speed.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Advanced Short Floor
0
ON(close)
<1>
S5-03
0
ON(close)
<1>
Not Available.
d1-19
(Nominal Speed)
Optimal Speed
d1-26
(Leveling Speed)
Time
d1-19
(Nominal Speed)
Optimal Speed
d1-26
(Leveling Speed)
Time