J1000
compact v/f control drive
200 v class, three-phase input: 0.1 to 5.5 kw
200 v class, single-phase input: 0.1 to 2.2 kw
400 v class, three-phase input: 0.2 to 5.5 kw (265 pages)
Compact vector control drive.
200 v class, three-phase input: 0.1 to 18.5 kw.
200 v class, single-phase input: 0.1 to 4.0 kw.
400 v class, three-phase input: 0.2 to 18.5 kw (44 pages)
Compact vector control drive.
models: 200 v class, three-phase input: 0.1 to 18.5 kw;
200 v class, single-phase input: 0.1 to 3.7 kw;
400 v class, three-phase input: 0.2 to 18.5 kw (427 pages)
Super energy-saving medium-voltage ac drive (260 pages)
Summary of Contents for YASKAWA CDBR-****D
Page 1
YASKAWA AC Drive Option Braking Unit, Braking Resistor Unit Installation Manual Type: CDBR- LKEB- To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. 安川インバータ オプション...
Page 2
Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice.
• LCD Keypad for YASKAWA AC Drive GA700, CH700, and CR700 • LED Keypad for YASKAWA AC Drive GA700, CH700, and CR700 ◆ Registered Trademarks Trademarks are the property of their respective owners. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 5
Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. NOTICE Indicates an equipment damage message. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 6
• Contact a Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cove to order new copies of the manual.
Page 7
Do not attempt to modify or alter the drive or option circuitry in any way not explained in this manual. Failure to comply could cause death or serious injury and will void warranty. Yaskawa is not responsible for any modification of the product made by the user. Do not modify this product.
Page 8
Burn Hazard Hot Surface Do not touch top and side surfaces which become ● hot during operation. Figure 1 Warning Information Figure 2 Figure 2 Warning Information Position YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
The CDBR Braking Unit is designed for use with the drive models in Table 1. It can also replace a spec B type CDBR. Contact Yaskawa or your Yaskawa agent for more information or to use the CDBR on drives not listed. Table 1 CDBR Braking Unit Applicable Models...
Page 10
■ The LKEB Braking Resistor Unit is designed for use with the drive models in Table Contact Yaskawa or your Yaskawa agent to use the CDBR on drives not listed. Table 2 LKEB Braking Resistor Unit Applicable Models Drive Series...
Refer to Figure 3 on page for details. Contact the distributor where the option was purchased or the Yaskawa sales office immediately about any problems with the option. ◆ Option Package Contents CDBR Braking Unit ■...
Page 12
Figure 3 Nameplate Example (CDBR Braking Unit) LKEB Braking Resistor Unit ■ Figure 4 Model Revision Max. Applicable Motor Figure 4 Nameplate Example (LKEB Braking Resistor Unit) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 13
22 (30) 37 (50) 200 V 55 (74) 110 (148) 30 (40) 45 (60) 400 V 90 (121) 220 (295) 37 (50) 600 V 110 (148) 300 (402) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 14
Resistance (Ω) Capacity (kW) Power (W) 0.75 200 V 2400 13.6 3000 18.5 4800 4800 0.75 400 V 1040 1560 18.5 4800 4800 27.2 6000 9600 9600 13.6 YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
D – Heatsink B – LED Display (Refer to page for details) E – Installation Hole C – Bottom Cover Figure 5 CDBR Braking Unit Components (Example: CDBR-2037D) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 16
A – Front Cover C – Heatsink B – LED Display (Refer to page for details) D – Installation Hole Figure 6 CDBR Braking Unit Components (Example: CDBR-2055D) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 17
D – Main Circuit Terminals I – N.O./N.C. DIP Switch S4 (B1, B2) E – Grounding Terminal J – Sink/Source DIP Switch S1 Figure 7 Front View of CDBR Braking Unit YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 18
CDBR is functioning as Slave SLAVE Green CDBR is functioning as Slave CDBR is functioning as Master DISABLE Fault has occurred Normal operation − CHARGE CDBR is powered on YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Failure to comply could cause ESD damage to circuitry. Do not connect or operate any equipment with visible damage or missing parts. Failure to comply could further damage the equipment. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 20
UL and CE standards. Install the braking unit in a pollution degree 2 environment or equivalent according to UL standards. Use UL Listed copper wires rated at 75°C (167°F) for main circuit terminal wiring (+, -, B1, B2) for UL approval. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 21
A – 50 mm (2.0 in) minimum C – 100 mm (3.9 in) minimum B – 30 mm (1.2 in) minimum D – Airflow direction Figure 9 CDBR Braking Unit Installation Spacing YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 22
C – 2 mm (0.08 in) minimum D – 120 mm (4.72 in) minimum B – 30 mm (1.18 in) minimum Figure 10 Space Between CDBR Braking Units (Side-by-Side Mounting) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 23
20P7 to 27P5 30 (1.18) 150 (5.91) 2011 to 2022 50 (1.97) 200 (7.87) 40P7 to 47P5 30 (1.18) 150 (5.91) 4011 to 4045 50 (1.97) 200 (7.87) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 24
Table 3 Dimensions for CDBR Braking Unit (IP20) Dimensions mm (in) Model Weight CDBR- kg (lb) 2022D 2037D 4030D (4.72) (5.91) (6.18) (4.13) (5.35) (0.28) (1.89) (0.24) (4.4) 4045D 5037D YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 34
Use the Retrofit Attachment to replace a CDBR-XB or CDBR-XC model CDBR Braking Unit. Contact your local Yaskawa representative to order the retrofit attachment. Retrofit Attachment Dimensions Figure 1 Figure 2 YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Failure to comply could cause death or serious injury. Do not use damaged wires, stress the wiring, or damage the wire insulation. Failure to comply could cause death or serious injury. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 39
Failure to comply could cause ESD damage to circuitry. Never connect or disconnect the motor from the drive while the drive is outputting voltage. Improper equipment sequencing could damage the drive. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 40
Failure to comply could prevent proper operation and damage equipment. Confirm that all connections are correct after installing the option and connecting peripheral devices. Failure to comply could damage the option. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 41
Push in on the hooks located on the sides of the front cover and gently pull forward. Figure 12 Figure 12 Push the Tabs Inward and Pull Forward on the Front Cover YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 42
Figure 13 Remove the Front Cover Pull forward on the bottom cover to remove it from the unit. Remove the bottom cover. Figure 14 Figure 14 Remove the Bottom Cover YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 43
C – Wiring space for ground terminals terminals B – Wiring space for LKEB braking D – Wiring space for main circuit resistor unit terminals Figure 15 Wiring Spaces YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 44
2. Separate CDBR Braking Unit and LKEB Braking Resistor Unit wiring from control wiring. Components Wiring Distance CDBR and LKEB < 10 m (32.8 ft.) Drive and CDBR < 5 m (16.4 ft.) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 45
Bottom Cover Wiring Space on page 43 for details. Figure 16 Control circuit terminals OUT1 OUT2 Main circuit terminals Ground terminals Figure 16 CDBR Wiring Terminals Confirm wiring connections. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 46
Insert the tab on the upper portion of the front cover to the corresponding opening, then connect the cover into place from the front of the unit. Figure 18 Figure 18 Reattach the Front Cover YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 47
6 Electrical Installation Tighten the screw to secure the front cover in place. Figure 19 Figure 19 Tighten the Front Cover Screw YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 48
<3> Set L8-01 to 1 to enable braking resistor overload protection in the drive when using ERF-type resistors. <4> Be sure to protect non-Yaskawa braking resistors by thermal overload relay. <5> Refer to the manual packaged with the drive for details on wiring ends. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 49
For 400 V class and 600 V class: 10 Ω or less <1> Use drive terminal B1 when installing the CDBR braking unit on the drive with built-in braking transistor. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 50
<1> Digital Input-SB, SC. Powered by internal 24 Vdc LVLC source. When using an external power supply, it shall be UL Listed Class 2 power source only or equivalent. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 51
(7.1 to 8.9) 4220D MA, MB, 5110D MC, EA, 5300D EB, EC 8 to 10 22 to 30 3 to 2 25 to 35 (70.8 to 88.5) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 52
<1> Junction terminals are needed to connect to the drives when terminals - and + are connected to the following drives. Contact Yaskawa or your nearest sales representative when selecting and connecting junction terminals. Drive models: CIPR-GA702169, 2211, CIPR-CH702145, 2180, CIPR-CR702145, 2180...
Page 53
Junction terminals are needed to connect to the drives if using a gauge that is smaller than the applicable range for gauges for the drives. Contact Yaskawa or your nearest sales representative when selecting and connecting junction terminals.
Page 54
<1> Connect directly to the drive or install a terminal block. <2> Connect the thermal relay trip contact to disconnect main input power to the drive. Note: Contact your Yaskawa representative or nearest agent when using the CDBR Braking Unit (CDBR-D) with earlier models (CDBR-, CDBR-B, or CDBR-C).
Page 56
NPN transistors (0 V common/sinking mode) and contacts using the drive internal power supply. Figure 23 A (N.O. (default)) B (N.C.) SINK-default +24 V SOURCE Figure 23 CDBR Braking Unit SINK Mode using Internal Power Supply YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 57
CDBR. Set DIP switch S2 to IN (Slave) on all other units in the circuit. Refer to Using CDBR Braking Units in Parallel on page 53 for details. Figure 25 IN (Slave) OUT (Master) Figure 25 Master/Slave Selection Switch (S2) YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 59
Confirm the required motor deceleration characteristics. The LEDs on the front confirm the operation state. Refer to CDBR Braking Unit LED Display on page 18 for details on the LEDs. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
- CDBR transistor overcurrent Ambient temperature exceeded 50°C (122°F). CDBR heatsink is too Reduce the ambient temperature. hot. The CDBR braking unit is damaged. Replace the CDBR braking unit. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 61
• Observe the Master and Slave LEDs when using slave units. The LEDs should blink when the CDBR is activating. The braking unit is damaged. Replace the CDBR braking unit. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
<2> Set L3-04 to 0 or 3 to disable Stall Prevention during deceleration when using an LKEB Braking Resistor Unit. Enabling the function under these conditions may prevent the drive from stopping within the specified deceleration time. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 63
<2> Set L3-04 to 0 or 3 to disable Stall Prevention during deceleration when using an LKEB Braking Resistor Unit. Enabling the function under these conditions may prevent the drive from stopping within the specified deceleration time. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 64
<4> Set one of the CDBR Braking Units as the master and set all others as slaves when using more than one CDBR Braking Unit connected in parallel. Note: Contact your Yaskawa representative or the nearest Yaskawa sales office when using a CDBR-XD model Braking Unit with CDBR-X or CDBR-XB models.
Page 65
Enabling the function under these conditions may prevent the drive from stopping within the specified deceleration time. <3> Wire the thermal relay trip contacts in parallel when connecting multiple LKEB Braking Resistor units. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Note: This mark will be added to factory shipments from late June 2016. There may be a mix of products that reflect or do not reflect this change during the distribution stage. Thank you for your understanding. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 67
Note: The CDBR Braking Unit complies with EU RoHS directives. In this table, “×” indicates that hazardous substances that are exempt from EU RoHS directives are contained. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
IP00 enclosure, IP20 enclosure, UL Type 1 enclosure Heatsink Loss (W) Interior Unit Loss (W) Total Watt Loss (W) <1> Adjustable by 10 incremental steps. <2> Not available for 600 V class models. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 70
Back cover Revision: Address Addition: Additional models added along with corresponding data May 2012 <2> 200 V: CDBR-2022D, 400 V: CDBR-2030D November 2011 <1> Revision: Reviewed and corrected entire documentation. YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 71
12 Specifications Date of Revision Section Revised Content Publication Number − − November 2011 First Edition YASKAWA ELECTRIC TOBP C720600 01E YASKAWA AC Drive Option CDBR-D, LKEB- Installation Manual...
Page 72
Phone: +81-3-5402-4502 Fax: +81-3-5402-4580 http://www.yaskawa.co.jp YASKAWA AMERICA, INC. 2121, Norman Drive South, Waukegan, IL 60085, U.S.A. Phone: +1-800-YASKAWA (927-5292) or +1-847-887-7000 Fax: +1-847-887-7310 http://www.yaskawa.com YASKAWA ELÉTRICO DO BRASIL LTDA. 777, Avenida Piraporinha, Diadema, São Paulo, 09950-000, Brasil Phone: +55-11-3585-1100 Fax: +55-11-3585-1187 http://www.yaskawa.com.br...
Need help?
Do you have a question about the CDBR-****D and is the answer not in the manual?
Questions and answers