YASKAWA L1000A Technical Manual page 404

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

B.3 Parameter Table
No.(Addr.)
Name
E4-02
Motor 2 Rated Slip
(322H)
E4-03
Motor 2 Rated No-Load Current
(323H)
E4-04
Motor 2 Motor Poles
(324H)
E4-05
Motor 2 Line-to-Line Resistance
(325H)
E4-06
Motor 2 Leakage Inductance
(326H)
<4> Default setting value is dependent on the drive model (o2-04).
<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU20008 to 20033, 40005 to 40018, and
50003 to 50013 display values in 0.01 A units, while models CIMR-LU20047 to 20415, 40024 to 40605, and 50017 to
50200 display values in 0.1 A units.
E5: PM Motor Settings
No.(Addr.)
Name
E5-02
(32AH)
Motor Rated Power
<1>
E5-03
(32BH)
Motor Rated Current
<1>
E5-04
(32CH)
Number of Motor Poles
<1>
E5-05
Motor Stator Resistance
(32DH)
(Single Phase)
<1>
E5-06
(32EH)
Motor d-Axis Inductance
<1>
E5-07
(32FH)
Motor q-Axis Inductance
<1>
E5-09
(331H)
Motor Induction Voltage Constant 1
<1>
E5-11
Encoder Offset
(333H)
E5-24
Motor Induction Voltage Constant 2
(353H)
<1> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Default setting value is determined by the drive model (o2-04).
<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU20008 to 20033, 40005 to 40018, and
50003 to 50013 display values in 0.01 A units, while models CIMR-LU20047 to 20415, 40024 to 40605, and 50017 to 50200
display values in 0.1 A units.
<43> When PG-E3 option connected: Max setting = 48
404
V/f
OLV
Sets the rated slip for motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the no-load current for motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the number of poles of motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the phase-to-phase resistance for motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the voltage drop for motor 2 due to motor leakage inductance as a percentage of rated
voltage. Automatically set during Auto-Tuning.
V/f
OLV
Sets the rated capacity of the motor.
V/f
OLV
Sets the motor rated current.
V/f
OLV
Sets the number of motor poles.
V/f
OLV
Sets the stator resistance (1 phase value).
V/f
OLV
Sets the d-axis inductance.
V/f
OLV
Sets the q-axis inductance.
V/f
OLV
Sets the induced phase peak voltage in units of 0.1 mV (rad/s) [electrical angle].
When setting this parameter, E5-24 should be set to 0.0.
V/f
OLV
Sets the offset between the rotor magnetic axis and the encoder zero position. Set during
Encoder Offset Tuning.
V/f
OLV
Sets the induced phase-to-phase rms voltage in units of 0.1 mV/(r/min) [mechanical angle].
When setting this parameter, E5-09 should be set to 0.0.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV/PM
CLV
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
Setting
Default:
<4>
common_
TMonly
Min: 0.00 Hz
Min: 20.00 Hz
Default:
<4>
common_
TMonly
Min: 0 A
Min: [E4-01]
<10>
Default: 4
common_
TMonly
Min: 2
Max: 48
Default:
common_
<4>
TMonly
Min: 0.000 Ω
Max: 65.000 Ω
common_
Default:
<4>
TMonly
Min: 0.0%
Max: 40.0%
Setting
Default:
<4>
common_
TMonly
Min: 0.10 kW
Max: 650.00 kW
Default:
<4>
Min: 10% of drive rated
common_
TMonly
current
Max: 200% of drive
rated current
<10>
Default: 12
common_
TMonly
Min: 2
Max: 120
<43>
Default:
<4>
common_
TMonly
Min: 0.000 Ω
Max: 65.000 Ω
Default:
<4>
common_
TMonly
Min: 0.00 mH
Max: 600.00 mH
Default:
<4>
common_
TMonly
Min: 0.00 mH
Max: 600.00 mH
Default:
<4>
common_
TMonly
Min: 0.0 mV/(rad/s)
Max:
6500.0 mV/(rad/s)
common_
Default: 0.0 deg
TMonly
Min: -180 deg
Max: 180 deg
Default:
0.0 mV/(r/min)
common_
TMonly
Min:
0.0 mV/(r/min)
Max:
6500.0 mV/(r/min)
Page
192
192
192
193
193
Page
193
193
193
193
194
194
194
194
194

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents