YASKAWA L1000A Technical Manual page 181

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

Figure 5.12
Figure 5.12 Settings at Low and High Speed during Deceleration (Leveling Speed is Selected)
C5-08: Speed Control Loop Integral Limit
Sets the upper limit for Speed Control Loop output as a percentage of the rated torque.
No.
C5-08
C5-16: Speed Control Loop Delay Time during Position Lock
Adjusts the delay applied to the torque reference output from Speed Control Loop during Position Lock. Increase this
setting gradually in increments of 0.01 when vibration is a problem. This parameter rarely needs to be changed.
No.
C5-16
Speed Control Loop Delay Time during Position Lock
C5-17, C5-18: Motor Inertia, Load Inertia Ratio
C5-17 and C5-18 determine the ratio of the machine inertia and the inertia of the motor being used.
No.
C5-17
C5-18
C5-19, C5-20: Speed Control Loop P Gain Time, I Time during Position Lock
These parameters adjust the responsiveness of Speed Control Loop during Position Lock. Increase C5-19 and shorten
C5-20 if the motor rolls back immediately after the brake releases. Decrease C5-19 and lengthen C5-20 if vibrations
occur.
No.
C5-19
Speed Control Loop Proportional Gain Time during Position Lock
C5-20
Speed Control Loop Integral Time during Position Lock
C5-50: Set Vibrational Frequency Filter
Mechanical resonance may cause a humming sound or vibration while the motor is running. A vibrational frequency filter
can be used to suppress certain audible noise or vibration due to mechanical resonance.
Sets the mechanical vibration filter frequency in units of 1 Hz. Set C5-50 to 0 (Hz) to disable the filter. A setting of 0 will
disable this parameter.
Note: Test equipment may be required to determine the mechanical resonance frequency. Setting C5-50 to an improper frequency will
result in ineffective filtering of the effects of mechanical resonance.
No.
C5-50
<1>
<1> Available in drive software versions PRG: 7200 or later.
<2> The frequencies from 1 to 19 Hz cannot be set.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
P, I
0
Parameter Name
Speed Control Loop Integral Limit
Parameter Name
Parameter Name
Motor Inertia
Load Inertia Ratio
Parameter Name
Parameter Name
Set Vibrational Frequency Filter
P = C5-01
I = C5-02
P = C5-13
I = C5-14
Speed
C5-07
Setting Range
0 to 400%
Setting Range
0.000 to 0.500 s
Setting Range
0.0001 to 600.00 kgm
0.0 to 6000.0
Setting Range
0.00 to 300.00
0.000 to 10.000 s
Setting Range
0 Hz, 20 to 1000 Hz
5.3 C: Tuning
common_
TMonly
Default
400%
Default
0.000 s
Default
2
Determined by o2-04
1.0
Default
Determined by A1-02
0.100 s
Default
0 Hz
<2>
5
181