B.3 Parameter Table
No.(Addr.)
Name
F1-50
(3D2H)
Encoder Selection
<39>
F1-51
PGoH Detection Level
(3D3H)
F1-52
Communication Speed of Serial
(3D4H)
Encoder Selection
<39>
F1-63
PG-E3 R Track Selection
(2DFH)
F1-66 to
F1-81
(B9AH to
Encoder Adjust 1 to 16
BA9H)
<44>
<5> Default setting is determined by the control mode (A1-02).
<34> Setting range is 1 to 15000 ppr when the drive is set for CLV/PM.
<39> Available in drive software versions PRG: 7016 or later.
<44> Available in drive software versions PRG: 7017 or later.
F3: Digital Input Card (DI-A3)
No.(Addr.)
Name
F3-01
DI-A3 Option Card Input Selection
(390H)
F3-03
DI-A3 Option Card Data Length
(3B9H)
Selection
F4: Analog Monitor Card (AO-A3)
No.(Addr.)
Name
F4-01
Terminal V1 Function Selection
(391H)
F4-02
(392H)
Terminal V1 Gain
F4-03
Terminal V2 Function Selection
(393H)
F4-04
(394H)
Terminal V2 Gain
406
V/f
OLV
Selects the encoder connected the PG-F3 option.
0: EnDat 2.1/01, 2.2/01 Serial Communication + Sin/Cos
1: EnDat 2.2/22 Serial Communication
2: HIPERFACE
V/f
OLV
Sets the level for detecting PG Hardware Fault (PGoH). Available when F1-20 = 1
V/f
OLV
Selects the communication speed between the PG-F3 option and serial encoder.
0: 1M bps/9600 bps
1: 500k bps/19200 bps
2: 1M bps/38400 bps
3: 1M bps/38400 bps
V/f
OLV
0: Disabled
1: Enabled
V/f
OLV
Sets encoder offsets 1 to 16 for the PG-E3 option card. These parameters are automatically set
by the execution of Auto-Tuning of PG-E3 encoder characteristics.
All Modes
0: BCD, 1% units
1: BCD, 0.1% units
2: BCD, 0.01% units
3: BCD, 1 Hz units
4: BCD, 0.1 Hz units
5: BCD, 0.01 Hz units
6: BCD customized setting (5 digit), 0.02 Hz units
7: Binary input
The unit and the setting range are determined by F3-03.
F3-03 = 0: 255/100% (-255 to +255)
F3-03 = 1: 40961/100% (-4095 to +4095)
F3-03 = 2: 30000/100% (-33000 to +33000)
When the digital operator units are set to be displayed in Hertz or user-set units (o1-03 = 2 or 3),
the units for F3-01 are determined by parameter o1-03.
All Modes
0: 8 bit
1: 12 bit
2: 16 bit
All Modes
Sets the monitor signal for output from terminal V1. Set this parameter to the last three digits of
the desired U- monitor. Some U parameters are available only in certain control modes.
All Modes
Sets the gain for voltage output via terminal V1.
All Modes
Sets the monitor signal for output from terminal V2. Set this parameter to the last three digits of
the desired U- monitor. Some U parameters are available only in certain control modes.
All Modes
Sets the gain for voltage output via terminal V2.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
Description
Description
Setting
common_
TMonly
Default: 0
Min: 0
Max: 2
Default: 80%
common_
TMonly
Min: 1%
Max: 100%
common_
TMonly
Default: 0
Min: 0
Max: 3
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
Default: 0
TMonly
Min: 0
Max: FFFF
Setting
common_
TMonly
Default: 0
Min: 0
Max: 7
common_
TMonly
Default: 2
Min: 0
Max: 2
Setting
common_
Default: 102
TMonly
Min: 000
Max: 999
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
Default: 103
TMonly
Min: 000
Max: 999
Default: 50.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Page
197
198
198
198
198
Page
198
199
Page
199
199
199
199