YASKAWA L1000A Technical Manual page 284

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

6.2 Drive Alarms, Faults, and Errors
Digital Operator Display
LED Operator
LCD Operator
UL3
UL4
Uv
voF
<1> Terminals H1, H2, DM+, and DM- on 600 V class models are designed to the functionality, but are not certified to IEC/EN 61800-5-2, ISO/EN
13849 Cat.3, IEC/EN 61508 SIL2, Insulation coordination: class 1.
<2> Output when H2- = 2F.
Operation Errors
Digital Operator Display
LED Operator LCD Operator
oPE01
oPE02
oPE03
oPE04
oPE05
oPE06
oPE07
Auto-Tuning Errors
Digital Operator Display
LED Operator LCD Operator
End1
End2
End3
End4
End5
End6
End7
End8
End9
End10
Er-01
Er-02
Er-03
Er-04
284
Undertorque Detection 1
Undertorque Detection 2
Undervoltage
Output Voltage Detection Error
Table 6.5 Operation Error Displays
Name
Drive Capacity Setting Error
Parameter Setting Range Error
Multi-function Digital Input Setting
Error
Terminal Board Mismatch Error
Reference Source Selection Error
Control Mode Selection Error
Multi-function Analog Input Selection
Error
Table 6.6 Auto-Tuning Error Displays
Name
Excessive V/f Setting
Motor Iron Core Saturation Coefficient
Error
Rated Current Setting Alarm
Adjusted Slip Calculation Error
Resistance Tuning Error
Leakage Inductance Alarm
No-Load Current Alarm
Rescue Operation Speed Warning
Rescue Operation Rotor Pole Position
Search Warning
Rescue Operation Rotor Polarity
Detection Warning
Motor Data Error
Alarm
STOP Button Input
Line-to-Line Resistance Error
Name
Digital Operator Display
Page
LED Operator LCD Operator
305
305
305
305
305
305
305
Digital Operator Display
Page
LED Operator LCD Operator
307
307
307
307
307
307
307
308
308
308
308
308
308
308
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Minor Fault Output
(H2- = 10)
YES
YES
YES
YES
Name
oPE08
Parameter Selection Error
oPE10
V/f Pattern Setting Error
oPE16
Energy Saving Constants Error
Parameter Setting Error, Online Tuning
oPE18
Parameter Setting Error
oPE20
PG-F3 Setting Error
oPE21
Elevator Parameter Setting Fault
Name
Er-05
No-Load Current Error
Er-08
Rated Slip Error
Er-09
Acceleration Error
Er-10
Motor Direction Error
Er-11
Motor Speed Error
Er-12
Current Detection Error
Er-13
Leakage Inductance Error
Er-18
Induction Voltage Error
Er-19
PM Inductance Error
Er-20
Stator Resistance Error
Er-21
Z Pulse Correction Error
Er-22
Initial Rotor Pole Search Error
Non-rotating Encoder Offset Tuning
Er-23
Warning
Page
303
303
304
304
Page
306
306
306
306
306
306
Page
308
309
309
309
309
309
309
309
310
310
310
310
310

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents