YASKAWA L1000A Technical Manual page 427

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No. (Addr.)
Name
S4-07
UPS Power
(6CDH)
S4-08
UPS Operation Speed Limit
(6CEH)
Selection
S4-12
DC Bus Voltage during Rescue
(6D2H)
Operation
S4-13
Rescue Operation Power Supply
(6D3H)
Deterioration Detection Level
S4-15
Speed Reference Selection for
(6DAH)
Rescue Operation
<39>
<5> Default setting is determined by the control mode (A1-02).
<39> Available in drive software versions PRG: 7016 or later.
S5: Short Floor Operation
No. (Addr.)
Name
S5-01
Short Floor Operation Selection
(6ABH)
S5-02
Nominal Speed for Short Floor
(6ACH)
Calculation
S5-03
Short Floor Minimum Constant
(6ADH)
Speed Time
S5-04
Distance Calculation Acceleration
(6AEH)
Time Gain
S5-05
Distance Calculation Deceleration
(6AFH)
Time Gain
S5-10
Stopping Method Selection
(6B0H)
S5-11
Deceleration Distance
(6B1H)
S5-12
Stop Distance
(6B2H)
S5-13
Direct Landing Minimum Speed
(6D6H)
Level
<36> When the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 650.00 inches.
<37> When the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 393.00 inches.
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
All Modes
Sets the capacity of the UPS.
All Modes
Determines how a speed limit should be applied to the Rescue Operation speed (S4-15) when
operating from a UPS.
0: Disabled
1: Enabled until Light Load Direction Search is complete
2: Enabled until stop
All Modes
Sets the DC bus voltage during Rescue Operation.
All Modes
Determines at which level of backup power supply deterioration a PF5 fault is triggered.
All Modes
Selects the speed reference used for Rescue Operation.
Description
All Modes
0: Disabled
1: Enabled (Short Floor)
2: Enabled (Advance Short Floor)
All Modes
When d1-18 (Speed Priority Selection) is set to 0 or 3, S5-02 determines the rated speed used
during Short Floor.
All Modes
Sets the minimum operation time when the Advanced Short Floor function is enabled (S5-01 =
2).
All Modes
Set for acceleration jerk compensation in Distance Calculation.
All Modes
Set for deceleration jerk compensation in Distance Calculation.
V/f
OLV
0: Disabled
1: Direct Landing
2: Leveling Distance Control
V/f
OLV
Sets the deceleration distance when Stop Distance Control is enabled.
V/f
OLV
Sets the stopping distance when Stop Distance Control is enabled.
V/f
OLV
Sets the speed level for the start of Direct Landing.
Direct Landing is essentially disabled if the starting speed for Direct Landing is less than the
maximum output speed multiplied by this parameter (E1-04 × S5-13).
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
Default: 0.0 kVA
common_
TMonly
Min: 0.0 kVA
265
Max: 100.0 kVA
common_
common_
TMonly
TMonly
Default: 2
Min: 0
265
Max: 2
Default: 0 V
common_
common_
TMonly
TMonly
Min: 0 V
266
Max: 1150 V
Default: 80%
common_
TMonly
Min: 10%
266
Max: 100%
Default: 0
common_
TMonly
Min: 0
266
Max: 1
Setting
Page
common_
TMonly
Default: 0
Min: 0
269
Max: 2
common_
Default: 0.0%
TMonly
Min: 0.0%
269
Max: 100.0%
common_
Default: 0.0 s
TMonly
Min: 0.0 s
269
Max: 2.0 s
Default: 150.0%
common_
TMonly
Min: 50.0%
269
Max: 200.0%
Default: 150.0%
common_
TMonly
Min: 50.0%
269
Max: 200.0%
common_
TMonly
Default: 0
Min: 0
272
Max: 2
Default: 0 mm
common_
TMonly
Min: 0 mm
272
Max: 32767 mm
<36>
Default: 0 mm
common_
TMonly
Min: 0 mm
272
Max: 10000 mm
<37>
common_
TMonly
Default: 20%
Min: 0%
272
Max: 100%
B
427