YASKAWA L1000A Technical Manual page 364

200 v class: 1.5 to 110 kw (2 to 150 hp) 400 v class: 1.5 to 315 kw (2 to 500 hp) 600 v class: 1.5 to 160 kw (2 to 250 hp)
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

8.4 Option Card Installation
Terminal Functions
Terminal Block
TB1
TB2
<1> A separate UL Listed class 2 power supply is necessary when the PG requires more than 200 mA to operate.
Setting the PG Encoder Power Supply Voltage
For the PG-X3 Option, set the voltage for the PG encoder power supply using jumper CN3 located on the option.
NOTICE: The positioning of jumper CN3 selects the PG encoder power supply voltage (5.5 V or 12 V). Select the voltage level for the
PG encoder connected to the option and motor. If the wrong voltage is selected, the PG encoder may not operate properly or may
become damaged as a result.
Table 8.9 Setting the PG Encoder Power Supply Voltage (IP) with Jumper CN3
Voltage Level
Jumper CN3
Wire Gauges and Tightening Torques
Wire gauge and torque specifications are listed in
the wire ends. Refer to the option manuals for the wire size and torque specifications of other options.
Screw
Terminal Signal
Size
A+, A–, B+,
B–, Z+, Z–,
SD, FE, IP, IG
M2
a+, a–, b+,
b–, z+, z–, SG
364
Table 8.8 Option Terminal Functions
Terminal
A+
A+ pulse signal input
A–
A– pulse signal input
B+
B+ pulse signal input
B–
B– pulse signal input
TB1
Z+
Z+ pulse signal input
Z–
Z– pulse signal input
SD
NC pin (open)
FE
Ground
IP
PG encoder power supply
IG
PG encoder power supply common
SG
Monitor signal common
a+
A+ pulse monitor signal
TB2
a–
A- pulse monitor signal
b+
B+ pulse monitor signal
b–
B- pulse monitor signal
z+
Z+ pulse monitor signal
z–
Z- pulse monitor signal
5.5 V ± 5% (default)
5.5 V 12 V
Table
Table 8.10 Wire Gauges and Tightening Torques
Tightening Torque
Nm
Applicable Gauges
(lb.in.)
mm
0.22 to 0.25
0.75
(1.95 to 2.21)
(18 AWG)
Function
• Inputs for the A channel, B channel, and Z pulses from the PG encoder
• Signal level matches RS-422
Open connection connectors for use when cable shields should not be
grounded
Used as the shield ground termination point.
• Output voltage: 12.0 V ± 5% or 5.5 V ± 5%
• Max. output current: 200 mA
• Output signal for monitoring A channel, B channel, and Z pulses from the
PG encoder
• Signal level matches RS-422
CN3
8.10. For simpler and more reliable wiring, use crimp ferrules on
Bare Cable
Recomm. Gauge
2
mm
2
Stranded wire:
0.25 to 1.0
(24 to 17 AWG)
Solid wire:
0.25 to 1.5
(24 to 16 AWG)
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
Description
<1>
12.0 V ± 5%
5.5 V 12 V
Crimp Terminals
Applicable Gauges
Recomm. Gauge
mm
2
mm
0.5
0.25 to 0.5
(20 AWG)
(24 to 20 AWG)
CN3
Wire Type
2
Shielded twisted
pair, etc.
Shielded cable,
etc.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents